4 Level 1 Display / Control Functions
•
At Level 1, the panel operates in a display only mode with the control keys disabled.
•
If fire alarm or fault conditions exist, the LED Indicators will show these. Detailed information will be
scrolled on the alphanumeric display.
•
The information on the alphanumeric display can be scrolled manually by pressing either the
>
(forward)
or the
<
(back) keys.
4.1 Normal
Conditions
•
When the system is in a normal condition, the green AC Power LED will be illuminated. The alphanumeric
display will show the time and date and will alternate between a user programmed text message and a
system status message.
4.2 AC Mains Power Fail Conditions
•
If the AC MAINS power source is interrupted, the AC Power LED will flash. In addition, the internal buzzer
will sound.
•
The back light illumination of the alphanumeric display will be turned off, the display will show an “AC Fail”
message and the Supply Fault LED and Fault LED Indicators will be lit.
•
If both the AC MAINS input and the Battery Standby Input fail then all LED and alphanumeric display
indicators will be off.
4.3 Fire Alarm Conditions
•
If the control panel initiates an alarm condition, the FIRE LED Indicators will be illuminated and, if
appropriate, the relevant ZONE FIRE LED Indicators will flash. The internal buzzer will sound and the
alphanumeric display will give detailed information regarding the fire alarm location.
•
If more than one fire alarm condition is present, the alphanumeric display will either automatically scroll
through or, can be manually scrolled through, the fire alarms registered.
4.3.1 Override Delays
EN54
9
EN54-2 7.11d
Override delays at
Level 1
•
If the ZX1E, ZX2E and ZX5E control panels are
configured to operate with delays to outputs, a
manual call point (MCP) will be located next to the
panel.
•
To override any delays and immediately activate the
bells and other fire alarm output devices, break the
glass in the call point.
BREAK GLASS
Press Here
FIRE
4.4 Fault
Conditions
•
If the panel detects a fault, the FAULT LED is illuminated along with other appropriate system condition
LED Indicators. The alphanumeric display gives detailed information regarding the nature of the fault and
the panel buzzer will sound.
•
If more than one fault condition is present, the alphanumeric display will either automatically scroll through
or, can be manually scrolled through, the faults registered.