background image

WARRANTY DISCLAIMER

THE COMPANY MAKES NO EXPRESS, IMPLIED OR STATUTORY WAR

-

RANTIES (INCLUDING ANY WARRANTY OF MERCHANTABILITY OR 

OF FITNESS FOR A PARTICULAR PURPOSE) WITH RESPECT TO ANY 

GOODS OR SERVICES SOLD BY THE COMPANY.  THE COMPANY DIS

-

CLAIMS ALL WARRANTIES ARISING FROM ANY COURSE OF DEALING 

OR TRADE USAGE, AND ANY BUYER OF GOODS OR SERVICES FROM 

THE COMPANY ACKNOWLEDGES THAT THERE ARE NO WARRANTIES 

IMPLIED BY CUSTOM OR USAGE IN THE TRADE OF THE BUYER AND 

OF THE COMPANY, AND THAT ANY PRIOR DEALINGS OF THE BUYER 

WITH THE COMPANY DO NOT IMPLY THAT THE COMPANY WARRANTS 

THE GOODS OR SERVICES IN ANY WAY.

 

ANY BUYER OF GOODS OR SERVICES FROM THE COMPANY 

AGREES WITH THE COMPANY THAT THE SOLE AND EXCLUSIVE REM

-

EDIES FOR BREACH OF ANY WARRANTY CONCERNING THE GOODS 

OR SERVICES SHALL BE FOR THE COMPANY, AT ITS OPTION, TO 

REPAIR OR REPLACE THE GOODS OR SERVICES OR REFUND THE 

PURCHASE PRICE.  THE COMPANY SHALL IN NO EVENT BE LIABLE 

FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES EVEN IF THE 

COMPANY FAILS IN ANY ATTEMPT TO REMEDY DEFECTS IN THE GOODS 

OR SERVICES , BUT IN SUCH CASE THE BUYER SHALL BE ENTITLED 

TO NO MORE THAN A REFUND OF ALL MONIES PAID TO THE COMPANY 

BY THE BUYER FOR PURCHASE OF THE GOODS OR SERVICES.  

RETURN PROCEDURES

 

ANY CAUSE OF ACTION FOR BREACH OF ANY WARRANTY BY 

THE COMPANY SHALL BE BARRED UNLESS THE COMPANY RE

-

CEIVES FROM THE BUYER A WRITTEN NOTICE OF THE ALLEGED 

DEFECT OR BREACH WITHIN TEN DAYS FROM THE EARLIEST DATE 

ON WHICH THE BUYER COULD REASONABLY HAVE DISCOVERED 

THE ALLEGED DEFECT OR BREACH, AND NO ACTION FOR THE 

BREACH OF ANY WARRANTY SHALL BE COMMENCED BY THE 

BUYER ANY LATER THAN TWELVE MONTHS FROM THE EARLIEST 

DATE ON WHICH THE BUYER COULD REASONABLY HAVE DISCOV

-

ERED THE ALLEGED DEFECT OR BREACH.

RETURN POLICY

For a period of thirty-six (36) months from the date of shipment, and under 

normal conditions of use and service, Moore Industries (“The Company”) 

will at its option replace, repair or refund the purchase price for any of its 

manufactured products found, upon return to the Company (transportation 

charges prepaid and otherwise in accordance with the return procedures 

established by The Company), to be defective in material or workmanship.  

This policy extends to the original Buyer only and not to Buyer’s customers 

or the users of Buyer’s products, unless Buyer is an engineering contractor 

in which case the policy shall extend to Buyer’s immediate customer only.  

This policy shall not apply if the product has been subject to alteration, 

misuse, accident, neglect or improper application, installation, or operation.  

THE COMPANY SHALL IN NO EVENT BE LIABLE FOR ANY INCIDENTAL 

OR CONSEQUENTIAL DAMAGES.

To return equipment to Moore Industries for repair, follow these four steps: 

 

1.  Call Moore Industries and request a Returned Material Authorization (RMA) number.

 

 

    Warranty Repair –

 

 

 

If you are unsure if your unit is still under warranty, we can use the unit’s serial number  

 

 

to verify the warranty status for you over the phone.  Be sure to include the RMA   

 

 

number on all documentation. 

 

    Non-Warranty Repair –

 

 

 

If your unit is out of warranty, be prepared to give us a Purchase Order number when  

 

 

you call.  In most cases, we will be able to quote you the repair costs at that time.  

 

 

 

The repair price you are quoted will be a “Not To Exceed” price, which means that the  

 

 

actual repair costs may be less than the quote.  Be sure to include the RMA number on  

  all 

documentation. 

2.  Provide us with the following documentation:

 

a)  A note listing the symptoms that indicate the unit needs repair

 

b)  Complete shipping information for return of the equipment after repair

 

c)  The name and phone number of the person to contact if questions arise at the factory

3.  Use sufficient packing material and carefully pack the equipment in a sturdy shipping con

-

tainer.

4.  Ship the equipment to the Moore Industries location nearest you. 

 

The returned equipment will be inspected and tested at the factory.  A Moore Industries 

representative will contact the person designated on your documentation if more informa-

tion is needed.  The repaired equipment, or its replacement, will be returned to you in ac

-

cordance with the shipping instructions furnished in your documentation.

United States • [email protected]

Tel: (818) 894-7111 • FAX: (818) 891-2816 

Australia • [email protected]

Tel: (02) 8536-7200 • FAX: (02) 9525-7296 

Belgium • [email protected]

Tel: 03/448.10.18 • FAX: 03/440.17.97

The Netherlands • [email protected]

Tel: (0)344-617971 • FAX: (0)344-615920

China • [email protected]

Tel: 86-21-62491499 • FAX: 86-21-62490635

United Kingdom • [email protected]

Tel: 01293 514488 • FAX: 01293 536852

Specifications and Information subject to change without notice.

© 2014 Moore Industries-International, Inc.

Содержание TDY

Страница 1: ...a n d M o o r e R e l i a b i l i t y All product names are registered trademarks of their respective companies User s Manual TDY PC Programmable Temperature Transmitter with Display No 235 740 00J M...

Страница 2: ...Europe Australia 16650 Schoenborn Street North Hills California 91343 6196 U S A Tel 818 894 7111 Fax 818 891 2816 E mail info miinet com TOLL FREE 1 800 999 2900 www miinet com 1 Lloyds Court Manor...

Страница 3: ...re 10 Gathering the Equipment Needed 10 11 PC Configuration Software Summary 12 Keeping What You ve Got Safe Using the Get Setup Function 13 Selecting Input Type Wiring etc 14 Scaling the Input also S...

Страница 4: ...Connected TDY 23 Installing and Connecting the TDY 24 Connecting the TDY in an Application 24 Recommended Ground Wiring Practices 24 CE Conformity 24 Dimensions 25 26 Installation in Hazardous Locatio...

Страница 5: ...by user designation inversely proportional to the input Available in your choice of explosion proof or NEMA 4X enclosures the TDY has certified protection in even the toughest environments Combine th...

Страница 6: ...isplay is always two decimal places Range 99999 to 99999 Minimum Display Span 1 00 Operating and Storage Range Transmitter 40 C to 85 C 40 F to 185 F Display 20 C to 65 C 4 F to 149 F Relative Humidit...

Страница 7: ...o 650 C 148 to 1202 F 200 to 630 C 328 to 1166 F 200 to 510 C 328 to 950 F 200 to 600 C 328 to 1112 F 200 to 630 C 328 to 1166 F 200 to 850 C 328 to 1562 F 80 to 320 C 112 to 608 F 50 to 250 C 58 to 4...

Страница 8: ...explosion proof enclosure with two inch entry ports and a glass cover BH2TG 2 Hub explosion proof enclosure with two inch entry ports and a glass cover BH2MG 2 Hub explosion proof enclosure with two M...

Страница 9: ...TDY Configuration Program on a PC Once the program is loaded and running nearly all of the operating parameters for the connected transmitter are shown on a single screen see Figure 3 This makes it ea...

Страница 10: ...verything is setup as shown in Figure 2 and it is not possible to store a tag name in the memory of a transmitter without connecting that transmitter to the Configuration Program Table 3 lists the thi...

Страница 11: ...Y COMM CABLE 803 040 26 FOR NON ISOLATED 803 039 26 FOR ISOLATED 804 030 26 FOR USB Thermocouple Millivolts Inputs 2 Wire RTD Direct Resistance Inputs 3 Wire RTD Direct Resistance Inputs 4 Wire RTD Di...

Страница 12: ...Software and will be used often The names and functions of the individual command buttons may change when you press a button 5 Output These scroll bars control the scaling and damping values of the T...

Страница 13: ...am Main Screen To save the Configuration File already resident in the transmitter s memory 1 Start the PC Configuration Program making sure that the TDY is connected as shown in Figure 2 2 Click on th...

Страница 14: ...tton at the bottom center of the screen then on the Prog button This transfers the settings from the software to the memory of the connected transmitter CAUTION Any time a connected TDY is programmed...

Страница 15: ...wnloaded Skip to Step 6 for instructions on getting the settings programmed into TDY nonvolatile memory 5 Select one of these options a Download the current settings into the connected transmitter s m...

Страница 16: ...ay Full The display zero and display full show what values will actually be displayed If the pull down menu in Figure 7 and the radio button on Figure 8 both have Input selected then Display Zero will...

Страница 17: ...Program Screen do not take effect in the unit until the Configuration File is downloaded Skip to Step 5 for instructions on getting the settings programmed into TDY nonvolatile memory 4 Choose from on...

Страница 18: ...it for it to capture the value 8 Click on the button labelled QuiInTrim then the Stop button and finally the Prog button to send the trim values to the transmitter Trimming the Output The TDY has a fu...

Страница 19: ...o this click on the Stop BW Stop Broken Wire Detection button when it is active on the bottom of the screen Setting Miscellaneous Functions Engineering Unit Readout Input Filtering Upscale or Downscal...

Страница 20: ...Main Screen or enter a value directly into the space provided The default damping value is 0 seconds The maximum allowable damping value is 5 056 seconds Using the Loop Test The TDY Loop Test feature...

Страница 21: ...l down menu to set Linearization ON Then click the CustTabl button in the lower left area of the Configuration Main Screen Figure 11 Linearization Must be set to ON to Create a Custom Table 3 Click on...

Страница 22: ...ests filling in the EGU Engineering Units then the number of points and finally the values in the table 9 When the table is complete click on the QuitTabl button and answer Yes on the pop up dialog bo...

Страница 23: ...e File button to bring up the File Management portion of the program 2 Use the Explorer like file display see Figure 13 to locate the file to be retrieved and click on the file to highlight it 3 Click...

Страница 24: ...output signals from Moore Industries productsshouldbewiredusingashielded twisted pair wiring technique Shields should be connected to an earth or safety ground For the best shielding the shield should...

Страница 25: ...Dimensions of the HP housing for the TDY unit 83 8 mm 3 30 in 118 1 mm 4 65 in 130 mm 5 12 in 111 8 mm 4 40 in 82 6 mm 3 25 in 63 5 mm 2 50 in C L Interior Diameter 81 3 mm 3 2 in 134 6 mm 5 30 in In...

Страница 26: ...TDY unit PS PS 1 2 3 4 SDY 16 203 MA 65mm 2 55 in GND 1 2 NPT 102mm 4 00 in 84mm 3 31 in 68mm 2 69 in 129mm 5 06 in 10mm 38 in 53mm 2 09 in 124mm 4 90 in 66mm 2 60 in 25mm 1 00 in 102mm 4 00 in 119mm...

Страница 27: ...lled as Division 2 equipment the TDY shall be mounted within a tool secured enclosure which meets the requirements of ANSI ISA 61010 1or C22 2 No 1010 1 and be capable of accepting the applicable wiri...

Страница 28: ...all be installed in an enclosure which maintains an ingress protection rating of at least IP20 The communications port shall be programmed through Moore Industries Cable Part No 804 030 26 as describe...

Страница 29: ...ale causes this message in the Output section of the Configuration Screen This condition is downloadable to the unit and causes transmitter output to rise proportionally in response to a drop on the i...

Страница 30: ...selves on their ability to provide timely accurate and practical answers to your process instrumentation questions Factory phone numbers are listed on the back cover of this manual If problems involve...

Страница 31: ...ng the intrinsically safe option It also in cludes guidelines for setting up zener barriers neces sary in these types of applications These diagrams must be used to augment the installa tion instructi...

Страница 32: ...TDY 32 Demand Moore Reliability...

Страница 33: ...TDY Demand Moore Reliability 33...

Страница 34: ...y and not to Buyer s customers or the users of Buyer s products unless Buyer is an engineering contractor in which case the policy shall extend to Buyer s immediate customer only This policy shall not...

Отзывы: