TCP/IP Interface Object (0xF5)
Moog Animatics Class 6 EtherNet/IP Guide, Rev. B
Page 72 of 160
Attrib
ID
Access
Rule
Name
Data
Type
Description
Semantics
5
(a)
Set/Get
(NV)
Interface Con-
figuration
STRUCT
of:
TCP/IP network inter-
face configuration.
Default Value: 0
Contains the con-
figuration parameters
required for a device to
operate as a TCP/IP
node.
IP Address(a)
UDINT
0 = no IP address has
been configured. Other-
wise, set IP address to
valid Class A, B, or C
address. Loopback
address (127.0.0.1) is
not allowed.
Network Mask
UDINT
The device’s network
mask
0 = network mask
address not configured
Gateway
Address
UDINT
Default gateway
address
0 = no gateway
address has been con-
figured. Otherwise, set
address to valid Class
A, B, or C address.
Loopback address
(127.0.0.1) is not
allowed.
Name Server
UDINT
Primary name server
0 = no name server
address has been con-
figured. Otherwise, set
address to valid Class
A, B, or C address.
Name Server 2
UDINT
Secondary name server 0 = no secondary name
server address has
been configured. Other-
wise, set address to
valid Class A, B, or C
address.
Domain Name
STRING Default domain name
ASCII characters. Max-
imum length is 48 char-
acters.
0 = no Domain Name is
configured.
6
Set/Get
(NV)
Host Name
STRING Host name.
Default Value: ""
ASCII characters. Max-
imum length is 64 char-
acters. Pad to an even
number of characters
(pad not included in
length).
0 = no Host Name is
configured.
Содержание SmartMotor SM34165MT-IP
Страница 16: ......
Страница 24: ......
Страница 30: ......
Страница 36: ......
Страница 98: ......
Страница 126: ......
Страница 153: ...SmartMotor AOI Example Moog Animatics Class 6 EtherNet IP Guide Rev B Page 153 of 160...
Страница 154: ......
Страница 158: ......
Страница 159: ......
Страница 160: ...PN SC80100010 001 Rev B...