Status LEDs
Status LEDs
This section describes the functionality of the Status LEDs on the Class 6 SmartMotor.
Off
No power
Solid green
Drive on
Blinking green
Drive off, no faults
Triple red flash
Watchdog fault
Solid red
Faulted or no drive enable input
Off
Not busy
Solid green
Drive on, trajectory in progress
Off
No/bad cable; no/bad Link port
Solid green
Link established
Flashing # red
Flashes fault code* (see below)
when Drive LED is solid red
Blinking green
Activity
Off
No/bad cable; no/bad Link port
Solid green
Link established
Blinking green
Activity
Off
No power
Flashing red/grn
Power-up self test
Flashing green
Standby
Solid green
Device operational
Flashing red
Minor fault
Solid red
Major fault
Off
No power or no IP address
Flashing red/grn
Power-up self test
Flashing green
No connections
Solid green
Connected
Flashing red
Connection timeout
Solid red
Duplicate IP
LED 4: EtherNet/IP Link 1 Input LED
LED 2: EtherNet/IP Network Status LED
LED 0: Motor Drive LED
LED 5: EtherNet/IP Link 2 Output LED
LED 3: EtherNet/IP Module Status LED
LED 1: Motor Busy LED
LED 0: Motor Drive LED
LED 1: Motor Busy LED
LED 3: EtherNet/IP Module Status LED
LED 5: EtherNet/IP Link 2 Output LED
LED 2: EtherNet/IP Network Status LED
LED 4: EtherNet/IP Link 1 Input LED
LED Status on Power-up:
• With no program and the travel limit inputs are low:
LED 0 solid red; motor is in fault state due to travel limit fault
LED 1 off
• With no program and the travel limits are high:
LED 0 solid red for 500 milliseconds then flashing green
LED 1 off
• With a program that only disables travel limits:
LED 0 red for 500 milliseconds then flashing green
LED 1 off
Flash
1
2
3
4
5
6
7
8
9
10
11
Description
NOT Used
Bus Voltage
Over Current
Excessive Temperature
Excessive Position
Velocity Limit
dE/Dt - First derivative of position error is excessive
Hardware Positive Limit Reached
Hardware Negative Limit Reached
Software Positive Travel Limit Reached
Software Negative Travel Limit Reached
LED1 Fault Codes:
*Busy LED pauses for 2 seconds before flashing the code
Flickering = On/Off in 0.1 sec; Blinking = On/Off in 0.5 sec; Flashing = separated by 1 sec for
EtherNet/IP LEDs and 2 sec for Fault Codes
USB Active LED
Flashing green
Active
Flashing red
Suspended
Solid red
USB power detected, no
configuration
USB Active LED
Moog Animatics Class 6 EtherNet/IP Guide, Rev. B
Page 29 of 160
Содержание SmartMotor SM34165MT-IP
Страница 16: ......
Страница 24: ......
Страница 30: ......
Страница 36: ......
Страница 98: ......
Страница 126: ......
Страница 153: ...SmartMotor AOI Example Moog Animatics Class 6 EtherNet IP Guide Rev B Page 153 of 160...
Страница 154: ......
Страница 158: ......
Страница 159: ......
Страница 160: ...PN SC80100010 001 Rev B...