SM6_Enable - Enable Drive
SM6_Enable - Enable Drive
Description
Set the Axis Drive Enable flag and wait for the Axis Drive Status flag to indicate the drive is
enabled.
Operands
Operand
Data Type
Operand Type
Description
SM6_Enable
SM6_Enable
Tag
Control tag for this AOI
Axis
SM6_Axis
Tag
The targeted drive
Structure
Field
Type
Description
.DN
BOOL
Set when the drive indicates the instruction has been processed.
.ER
BOOL
Set if there are any timeout errors.
Operation
Scan Mode
Description
Prescan
Reset timeout.
Rung-condition-in is FALSE
Reset timeout.
Rung-condition-in is TRUE
Set the Axis Drive Enable flag. Set the .DN output when the
Axis Drive Status Enable flag is set.
Moog Animatics Class 6 EtherNet/IP Guide, Rev. B
Page 110 of 160
Содержание SmartMotor SM34165MT-IP
Страница 16: ......
Страница 24: ......
Страница 30: ......
Страница 36: ......
Страница 98: ......
Страница 126: ......
Страница 153: ...SmartMotor AOI Example Moog Animatics Class 6 EtherNet IP Guide Rev B Page 153 of 160...
Страница 154: ......
Страница 158: ......
Страница 159: ......
Страница 160: ...PN SC80100010 001 Rev B...