SM6_Move_Position_Ext - Position Move(Extended Command)
Structure
Field Type
Description
.DN
BOOL Set when the drive indicates the instruction has been processed.
.ER
BOOL Set if there are any timeout or processing errors.
.IP
BOOL In Progress—set while the drive is reporting a command is in progress.
.MC
BOOL Move Complete—set when there is no move in progress and the drive is on the
target position.
Operation
Scan Mode
Description
Prescan
Initialize variables.
Rung-condition-in is FALSE
Initialize variables.
Rung-condition-in is TRUE
Send the Extended Move Position message to the drive and mon-
itor move progress.
NOTE:
This command requires a connection size of 32 bytes.
Moog Animatics Class 6 EtherNet/IP Guide, Rev. B