Diagnostic Codes
Hex
Value
Decimal
Value
Description
C01F0006
-1071710202
Instance of the CC object could not be created; no free
memory available
C01F0007
-1071710201
Completing a Connection Close command failed; sending
the command to the packet queue failed
C01F0008
-1071710200
Completing a Connection Open command failed; sending
the command to the packet queue failed
C01F0009
-1071710199
Sending the Delete Transport command failed; Encap
Queue signal an error
C01F000A
-1071710198
Sending the Forward Open command failed; Encap Queue
signal an error
C01F000B
-1071710197
Sending the Start Transport command failed; Encap
Queue signal an error
C01F000C
-1071710196
Connection manager received a confirmation of unknown
service
C01F000D
-1071710195
Sending the Forward Close command failed; Encap Queue
signal an error
C01F000E
-1071710194
Failed the Complete Reset command; did not get a empty
packet
Moog Animatics Class 6 EtherNet/IP Guide, Rev. B