To Show Calibration Voltages:
After communications are established and the acceptor has been enabled, press the V key. A display similar
to the one below will appear on the computer display.
Top Vis Voltage = 1.99 Volts (102) ee pot: 12/31
Top IR Voltage = 1.97 Volts (101) ee pot: 09/31
Bottom Vis Voltage = 1.97 Volts (101) ee pot: 16/31
Bottom IR Voltage = 1.99 Volts (102) ee pot: 19/31
Left Front Voltage = 4.70 Volts (target=4.72 V) DAC Setup = 107/255
Right Front Voltage = 4.70 Volts (target=4.72 V) DAC Setup = 125/255
IR Density Voltage = 4.70 Volts (target=4.72 V) DAC Setup = 73/255
Red Density Voltage = 4.72 Volts (target=4.72 V) DAC Setup = 170/255
String Detect Voltage = 2.34 Volts (target=2.34 V) DAC Setup = 94/255
IR Density Calibration: Slope=058, Diffusion 0.46, Cal Open V=4.72
Red Density Calibration: Slope=109, Diffusion Offset=-0.27, Cal Open V=4.70
****** CALIBRATION PASSED ******
PRESS <ENTER> TO CONTINUE...
Current Mag Gain Value = 23
DIP Switch1: 1 2 3 4 5 6 7 8
off off off off off off off off
DIP Switch2: 1 2 3 4 5 6 7 8
off off on off off on off off
Table 4-4. Diagnostic (Bench) Mode Voltage Printout
Содержание Ardac IBA5
Страница 13: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 1 8...
Страница 30: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 3 2 Figure 3 1...
Страница 31: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 3 3 Figure 3 2...
Страница 33: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 3 5 Figure 3 3...
Страница 66: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 7 4...