Specification and Adjustment Manual - ARDAC IBA5
Document Number 44X501R2 – March 15, 2004
1-16
SWITCH BANK 1
SWITCH OFF (Enable)
SWITCH ON (Inhibit)
SWITCH 1-1
NOTE 1 (Lowest Value)
ACCEPT NOTE 1
INHIBIT NOTE 1
SWITCH 1-2
NOTE 2
ACCEPT NOTE 2
INHIBIT NOTE 2
SWITCH 1-3
NOTE 3
ACCEPT NOTE 3
INHIBIT NOTE 3
SWITCH 1-4
NOTE 4
ACCEPT NOTE 4
INHIBIT NOTE 4
SWITCH 1-5
NOTE 5
ACCEPT NOTE 5
INHIBIT NOTE 5
SWITCH 1-6
NOTE 6
ACCEPT NOTE 6
INHIBIT NOTE 6
SWITCH 1-7
NOTE 7
ACCEPT NOTE 7
INHIBIT NOTE 7
SWITCH 1-8
UNDEFINED
UNDEFINED
UNDEFINED
SWITCH BANK 2
SWITCH OFF
SWITCH ON
SWITCH 2-1
PROTOCOL*
NETPLEX
PULSED (IBA4 only)
SWITCH 2-2
BARCODE
ENABLE
DISABLE
SWITCH 2-3
MAG SENSOR
DISABLED
ENABLED
SWITCH 2-4
STRING SENSOR
ENABLE
DISABLE
SWITCH 2-5
SMART CASSETTE
DISABLE
ENABLE
SWITCH 2-6
FIRMWARE DEVICE
EPROM
FLASH
SWITCH BANK 2-7 AND 2-8
FUNCTION
SW2-7 = OFF, SW2-8 = OFF
NORMAL OPERATION
SW2-7 = OFF, SW2-8 = ON
CALIBRATION CARD MODE
SW2-7 = ON, SW2-8 = OFF
CLEANING CARD MODE
SW2-7 = ON, SW2-8 = ON
UNDEFINED
* IBA5 Operates in Netplex protocol only.
Table 1-1
Содержание Ardac IBA5
Страница 13: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 1 8...
Страница 30: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 3 2 Figure 3 1...
Страница 31: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 3 3 Figure 3 2...
Страница 33: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 3 5 Figure 3 3...
Страница 66: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 7 4...