Specification and Adjustment Manual - ARDAC IBA5
Document Number 44X501R2 – March 15, 2004
4-7
NETPLEX Host Simulator Set-up
After the connections have been made using the 2x6434 interface board, ensure that the note acceptor and
cassette are installed and fully seated in the chassis. Then proceed with the following steps:
1. Apply power to the computer. Allow the computer to boot and load operating system.
2. Start the Host Simulator by running the HOST.EXE file from the DOS prompt or by creating and using a
shortcut on your windows desktop. Configure the software for the serial port where the CAPS interface is
connected, with the communication parameters 19,200 baud, odd parity, 8 data bits, and 1 stop bit (19,200,
O, 8, 1).
3. The software will start in Auto-Polling Mode unless this mode was disabled during a previous operating
session. The “From Host”, “From Computer”, and “Communications” windows will show the polling
activity.
- If Auto-Polling is ON, proceed to step 4.
- If Auto-Polling is OFF, press the F3 function key to access the Options Menu. Select Auto-Polling
from the menu options and press the Enter key. When Auto-Polling starts, proceed to step 4.
4. Apply power to the IBA5, and wait for the stacker punch twice indicating completion of the power-up
sequence.
5. To enable the acceptor, hit the <SHIFT> and <3> keys to produce the “#” symbol (may be different on
foreign keyboards). The bench software will allow the acceptor to accept notes and show denominations.
Diagnostic (Bench) Mode
1. The diagnostics or “Bench” mode on an IBA5 can only be accessed by connecting a 2X5665 interface
board to the flat 9 pin connector on the chassis as shown in Fig. 4-2. The switches on the interface board
should be set as follows:
1
2
3
4
5
6
7
8
SW-1 OFF OFF OFF OFF
ON ON
OFF OFF
SW-2 OFF OFF OFF OFF OFF OFF OFF OFF
A serial communications program such as Windows Hyper Terminal set to 19,200 baud, odd parity, 8 data
bits and one stop bit should be used to access the diagnostics mode. After the IBA5 completes power-up,
start Diagnostic (Bench) mode by hitting <ESC> <ESC> <ESC> <B>
2. The <B> key alternately toggles bench mode ON and OFF.
3. Pressing the <ENTER> key by itself while in diagnostics will display a block of information containing the
following information:
Содержание Ardac IBA5
Страница 13: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 1 8...
Страница 30: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 3 2 Figure 3 1...
Страница 31: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 3 3 Figure 3 2...
Страница 33: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 3 5 Figure 3 3...
Страница 66: ...Specification and Adjustment Manual ARDAC IBA5 Document Number 44X501R2 March 15 2004 7 4...