![Mobile Industrial Robots MiR Series Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/mobile-industrial-robots/mir-series/mir-series_troubleshooting-manual_1815283007.webp)
Troubleshooting guide (en) 07/2020 - v.1.1 ©Copyright 2019-2020: Mobile Industrial Robots A/S.
7
MiR100 and MiR200
Error code
Error type
Description
Solution
101, "CPU load
is too HIGH -
Above 90% for
more than 3
minutes"
Hardware
error.
Can resolve
itself.
An issue has occurred in
the robot software,
requiring unusual
amounts of processing
power.
Reboot the robot. If the problem
persists, and you have not updated to
the latest software, it is recommended
to update your robot. this may solve
the issue.
If the issue occurred after a software
update to the latest version, try to roll
back to a functioning software version
and report the issue to Technical
Support.
201, "Free
Memory is
VERY low"
Hardware
error.
Can resolve
itself.
An issue has occurred in
the robot software.
Reboot the robot. If the problem
persists, and you have not updated to
the latest software, it is recommended
to update your robot. this may solve
the issue.
If the issue occurred after a software
update to the latest version, try to roll
back to a functioning software version
and report the issue to Technical
Support.
301, "No
ethernet
adapter found"
Hardware
error.
Can resolve
itself.
An issue has occurred in
the robot computer.
Reboot the robot. If this does not solve
the issue, contact Technical Support.