Error code
Error type
Description
Solution
2113, "Voltage
monitor: 24V"
Hardware
error.
Can resolve
itself.
The 24 V power supply
is faulty.
See the solution in
monitor: 12V" on the previous page
2114, "Voltage
monitor: 3v3"
Hardware
error.
Can resolve
itself.
The 3.3 V power supply
is faulty.
See the solution in
monitor: 12V" on the previous page
2115, "Voltage
monitor: TOP_
FUSE"
Hardware
error.
Can resolve
itself.
The voltage delivered to
the top application
interface is outside the
limits.
Check CAB-041 (see
) that
leads from the power board to the
top application interface. if no faults
are found in the cable
2116, "Voltage
monitor: 5V0"
Hardware
error.
Can resolve
itself.
The 5 V power supply is
faulty.
See the solution in
monitor: 12V" on the previous page
2117, "Voltage
monitor:
<MC_
Logic/MC_
TOP>
"
Hardware
error.
Can resolve
itself.
Too much power is
being drawn from the
top application. Over 2
A and the fuse will burn
over.
Inspect your top application. Contact
your top application distributor for
assistance. When you are sure that
the top application will not burn the
fuse again, you can replace the fuse
with a new 2 A fuse. To replace the
fuse, you must unmount the power
board, remove the cover, locate the
green fuse in the back of the board,
replace it, and mount the power
board back in the robot.