(6) Ethernet connection
• Strip the outer insulation layer at both ends of the cable by the length shown below to expose the braided
shield for grounding. (For grounding with cable clamps. (refer to Section 5.4.3.))
• Attach the ferrite core to the cable in the position as illustrated below.
(a) When connecting to the Ethernet interface
(b) When connecting to the multimedia unit (GT16M-MMR)
(7) External I/O device connection
• Strip the outer insulation layer at both ends of the cable by the length shown below to expose the braided
shield for grounding. (For grounding with cable clamps (Refer to Section 5.4.3.))
• Connect the braided shield to the connector with the connector cover.
• Twist power cables.
GOT side
PLC/
personal computer side
Ferrite Core
(ZCAT3035-1330)
120 or
less
(4.72)
230 or less
(9.06)
400 or less
(15.75)
(1.57)
40
(1.57)
40
Unit : mm (inch)
120 or
less
(4.72)
GOT side
Personal computer side
Ferrite Core
(ZCAT3035-1330)
120 or
less
230 or less
(9.06)
(1.57)
40
Unit : mm (inch)
120 or
less
Connector cover
Braided shield
GOT side
External I/O device side
360 or less
360 or less
40
40
Unit : mm (inch)
Power cable
(14.17)
(14.17)
(1.57)
(1.57)
Содержание GOT 1000 GT16
Страница 1: ...GT16 User s Manual Hardware ...
Страница 2: ......
Страница 14: ...A 12 INDEX REVISIONS WARRANTY ...
Страница 193: ...10 3 Error Message and System Alarm 10 29 9 MAINTENANCE AND INSPECTION 10 TROUBLESHOOTING APPENDICES ...
Страница 210: ...App 17 ...
Страница 212: ...Index 2 Transportation Precautions App 15 U USB environmental protection cover 2 17 8 19 ...
Страница 217: ......