5 - 19
5.4 Precautions for Wiring/Connecting the EMC Directive-Compliant Product
(8) Video/RGB connection
(a) Video input
• Peel the sheath (with the length shown below) at both ends of the cable, and expose the shield braided
wire for grounding. (For grounding with cable clamps. (refer to Section 5.4.3.))
• Attach the ferrite core to the cable in the position as illustrated below.
(b) RGB input
• Wind cable shield material around the cable, and pull out the grounding braided wire of the cable shield
material with the length shown below.
• Attach the ferrite core to the cable in the position as illustrated below
(c) RGB output
• Wind cable shield material around the cable, and pull out the grounding braided wire of the cable shield
material with the length shown below.
• Attach the ferrite core to the cable in the position as illustrated below.
(HF90T28X13X16)
(1.57)
(1.57)
130 or less
GOT side
Camcorder/
Vision sensor side
Ferrite Core
Ferrite Core
(ZCAT3035-1330)
230 or less
400 or less
40
40
130 or less
(5.12)
(5.12)
Unit : mm (inch)
(15.75)
(9.06)
GOT side
Vision sensor/
personal computer
40
or less
130 or less
Unit : mm (inch)
Ferrite Core
(ZCAT3035-1330)
Grounding braided wire
(50mm)
Cable shield material
40
or less
130 or less
(5.12)
(1.57)
(5.12)
(1.57)
GOT side
external display side
200 or less
20 or less
20 or less
200 or less
Unit : mm (inch)
Ferrite Core
(ZCAT3035-1330)
Grounding braided wire (50mm)
Cable shield material
(7.87)
(7.87)
(0.79)
(0.79)
Содержание GOT 1000 GT16
Страница 1: ...GT16 User s Manual Hardware ...
Страница 2: ......
Страница 14: ...A 12 INDEX REVISIONS WARRANTY ...
Страница 193: ...10 3 Error Message and System Alarm 10 29 9 MAINTENANCE AND INSPECTION 10 TROUBLESHOOTING APPENDICES ...
Страница 210: ...App 17 ...
Страница 212: ...Index 2 Transportation Precautions App 15 U USB environmental protection cover 2 17 8 19 ...
Страница 217: ......