149
-
'11 • KX-T-166
•
Procedure on tightening harness (snubber capacitor) and power transistor with screw.
A metallic connection binder is set in each hole of the inverter PCB of "P", "N", "U", "V", and "W"
beforehand. Then tighten the harness (snubber capacitor) and the power transistor with the screw together.
(Connect snubber capacitor with "P" and "N".)
Installation Method to Power transistor
Terminal
Inverter PCB
Connection binder
Snubber capacitor
Harness
Power transistor
(Metallic pillar)
PCB
PCB voltage measurement point
PCB voltage measurement point
Fig.1 Voltage Measurement Points