'14 • KX-SM-200
-
5
-
-
-
Code
No.
Remarks
Displays No. of the protection control of which effect is the strongest
among those occurred from the start of operation after the power on
Displays No. of the protection control of which effect is stronger thirdly
among those occurred from the start of operation after the power on
Displays No. of the error detection of which effect is the strongest among
those occurred from the start of operation after the power on
Displays No. of the error detection of which effect is stronger secondly
among those occurred from the start of operation after the power on
Displays No. of the error detection of which effect is stronger thirdly
among those occurred from the start of operation after the power on
Displays No. of the protection control of which effect is stronger secondly
among those occurred from the start of operation after the power on
Contents of display
Data display
range
Minimum
unit
C70
C71
C72
C73
C74
C75
C80
C82
C84
C86
C88
C92
0~127
0~127
1
Protection control causes 1
Compressor error causes 1
Counter · Indoor-heat source unit communications error
Protection control causes 2
1
Protection control causes 3
0~127
1
0~127
1
Compressor error causes 2
0~127
1
Compressor error causes 3
0~127
1
Counter · Current cut (CM1)
0~255
1
EEPROM memory. Resettable.
Counter · Power transistor overheat (CM1)
Counter · Compressor startup failure (CM1)
Counter · Anomalous compressor by loss of
synchronism (CM1)
Counter · Communication error between inverter
PCB and heat source unit control (CM1)
0~255
0~255
0~255
0~255
0~255
1
1
1
1
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
EEPROM memory. Resettable.
C93
0~255
—
Counter · Heat source unit CPU reset
'14 • KX-SM-200
< Information for unusual counter >
< The other >
C96
C98
0.00~9.99
0.01
—
—
—
Program sub-version
Program POL version
C97
C99
Auto send display
Data reset
0~991
—
—
—
—
P01
Switching to operation priority
P04
P06
—
1
1
1
1
1
CNZ1 function assignment
CNS1 function assignment
CNS2 function assignment
CNG1 function assignment
CNG2 function assignment
0: External operation input
1: Demand input
2: Cooling/heating forced operation input
Many steps demand setting (2 step demand or
OFF: (Usually)
000,040,060,080
0: (Factory default)
0 ~ 9
P07
P08
P09
P10
< User setting >
energy save control)
0: (Factory default)
0 ~ 20
1: (Factory default)
0 ~ 20
2: (Factory default)
0 ~ 20
3: (Factory default)
0 ~ 20
—
—
< 7-segment software input >
4: Oil return control forced operation input
6: Test run external input 1 (SW5-1 equivalent)
7: Test run external input 2 (SW5-2 equivalent)
8: Silent mode input 2
9: 2-step demand input
10: AF periodic inspection display
11: AF error display
12: Building multi energy save control
13~20:Spare
—