8
CC IE Control UTILITY
8
- 20
8.4 Setting Screen
8.4.5 Supplementary setting screen
8.4.5
Supplementary setting screen
This screen is displayed by clicking the
button on the "Network
range assignment" screen.
Section 8.4.2 Network range assignment screen
It is used to set the constant link scan time, block data assurance per station, punctuality
assurance, and maximum number of transients in one station.
*1: If a longer constant link scan time is set, an error may be detected on 'baton pass status of each
station' (SW00A0 to SW00A7) and 'cyclic transmission status of each station' (SW00B0 to
SW00B7) of all stations for approximately 300ms + 1 link scan time when the personal computer
or board is reset.
*2: The separation prevention refers to a prevention of link data with double words (32 bits), such as
the current value of the positioning module, from being separated to new data and old data in units
of one word (16 bits) due to the refresh timing of cyclic transmission.
*3: The following table indicates the link scan operation with or without punctuality assurance.
Item
Description
Default
Setting range
Constant scan
*1
Maintains constant link scan time.
Set when a user does not wish a variation in link scan
time.
No setting
1 to 500
Block data assurance
per station is available
Select to prevent separation of link data by each
station at cyclic transmission.
*2
Checked
Checked
Unchecked
Transient setting
Set the executing condition of transient transmission.
—
—
Punctuality is
guaranteed
*3
Set whether punctuality is assured or not.
Unchecked
Checked
Unchecked
Maximum No. of
transients in one
station
Set the number of transients that can be executed
during one scan for a single station.
2
1 to 10
Reflects the settings, and closes the "Supplementary
setting" screen.
—
—
Without reflecting the settings, closes the
"Supplementary setting" screen.
—
—
Punctuality assurance
Link scan operation
With assurance
• Constant link scan time is maintained.
• Link scan time is longer than the setting without assurance.
• Link scan time becomes longer as the larger number is set for "Maximum No. of transients in one station".
Without assurance
• A variation in link scan time occurs when a transient transmission is requested.
• A variation in link scan time becomes larger as the larger number is set for "Maximum No. of transients in
one station".
Supplementary setting