V
Electrical Wiring Diagram ]
- 95 -
HWE0803A
GB
(3) PURY-P72, P96, P120YHMU-A
G
G
G
Ground
purple
X1
1
X12
3
5
6
1
CN509 blue
1
CN510 yellow
X09
X10
3
5
6
CN508 black
Unit address setting
CN504 green
CT12
C31
C33
CN5
red
D1
R5
Z5
Power Source
3~
60Hz
460V
SV4b
R631
1
3
white
T
ransformer Box
X13
2
CN07
1
2
3
4
4
CN06
8
CNTR1
3
1
4
1
T02
(T
ransformer)
CNTR2
3
7
12
6
6
5
2
white
red
black
black
white
red
F4
600V
3A
F
C8
F5
600V
3A
F
red
CNIT
yellow
CNS2
1
1
LED1 Display
setting
CN51
12V
Function setting
SW1
10
1
CN212
CNTYP4
green
F4
AC250V
6.3A
T
R4
F3
F1
Z4
R2
F2
*3
3
2
Compressor ON/OFF output
Error detection output
CN201
Z25
1
4
1
1
1
TH3
Z3
3
Z2
U
ON
OFF
SW2
10
1
SWU2
LED1
4
C4
C35
C37
R31
R33
R30
ON
SW3
10
Control Board
TH7
CN40
63HS1
CN41
TH6
TH4
3
2
2
2
1
SW5
LED3:Lit when powered
1
3
4
R32
2
Z1
1
1
DSA
C10
R34
R35
C36
3
C34
SC-V
CT22
SC-U
CN6
yellow
V
1
CN4
blue
red
1
1
1
L3
LED3:CPU in
operation
black
4
1
CNTYP2
black
3
6
yellow
CN3K
*3
3
C3
TB21
C1
R3
3
CN1A
5
U
CN2
blue
CN3N
5
6
C7
U
4
4
R1
CN21
blue
TB1
1
CN1B
3
3
TB7 Power
selecting
connector
CN102
CNVDC
THBOX
3
2
1
IPM
2
2
1
U
4
TP1
W
L3
DCL
V
black
72C
white
red
3
3
2
1
ON
OFF
12
M-NET
power
supply circuit
1
2
3
C6
M-NET
Board
1
2
1
Power failure detection circuit
1
CNAC2 black
CN502
5
Indoor/Outdoor
transmission
cable
INV Board
red
3
CNT01
TB23
L2
L1
U
4
1
ON
1
2
1's
digit
THHS
1
CNIT
red
S
2
1
1
CN990
1
3
W
TB3
10's
digit
OFF
LED2:CPU in operation
5
2
CNS2
yellow
TB7
1
CNDC
pink
M1
2
2
red
6
3~
MS
1
1
C100
*5
3
3
U
1
4
LED1:Power supply to
Indoor/Outdoor transmission line
SV4d
ZNR01
M2
32
M1
black
Central control
transmission
cable
*6
SC-L1
1
4
C2
C9
ON
C5
OFF
FT
-N
R5
M 3~
Motor
(Compressor)
CN5V
yellow
5
2
3
3
3
red
CN3S
1
1
CN04
red
1
CN2
2
3
CN4
X05
2
2
Fan motor
(Heat exchanger)
SC-P2
P
1
CN21
1
CN202
red
TH5
N
CN1
M2
2
TP2
SV4c
LED1:Normal operation(Lit)
/ Error(Blink)
2
CN503 blue
5
X04
4
*4
SC-W
U
C32
SC-L3
CH1
1
CN506
1
2
CN72
red
3
P
63H1
CN801
yellow
1
2
CN332
blue
F1,F2,F3
AC250V
6.3A
T
2
1
OFF
SW4
10
black
1
CNT02
11
CN3D
4
3
2
1
21
CPU power supply circuit
CNAC
red
2
1
F01
AC250V
3.15A
T
1
CN507 red
ON
OFF
10
SWU1
white
CN213
red
SC-L2
3
Z24
7
4
3
2
1
1
2
2
7
1
SV2
2
CN5
1
CN4
red
CNINV
3
4
R630
1
1
C630
white
3
red
CN22
red
C631
5
F01
DC700V
4A
T
1
CNTYP5
green
4
LED2:Error
21S4a
1
LED1:Normal
operation
2
3
2
U
X02
X03
CN18V
blue
5
1
3
7
CN4
3
CN6
2
IGBT
4
SC-P1
FT
-P
black
C30
red
Diode Bridge
CT3
72C
C1
CN2
CNTYP
black
R1
black
TB22
6
3
RSH1
CN102
3
R6
C17
1
1
1
F
AN Board
63LS
ZNR1
U
L
3
Noise Filter
SV5b
L3
L2
L1
X08
3
SV4a
SV9
X07
3
5
6
460V
1
3
4
2
CNTR3
T03
(T
ransformer)
6
5
6
5
L3
L1
L2
L2
L2
L1
purple
460V
SV1a
*7
1
SV5c
SV5b
<Symbol explanation>
DCL
SV1a
SV4a,b,c,d
CT12,22,3
CH1
1
72C
63LS
63HS1
63H1
Symbol
21S4a
SV2
SV5c
THBOX
Z24,25
THHS
TH7
TH6
TH5
TH4
TH3
TB7
TB3
TB1
SV9
DC reactor
Solenoid valve
Crankcase heater(for heating the compressor)
Current sensor(AC)
Magnetic relay(inverter main circuit)
Low pressure
Discharge pressure
High pressure protection for the
outdoor unit
Pressure switch
Pressure sensor
Explanation
4-way valve(Cooling/Heating switching)
For opening/closing the bypass
circuit under the O/S
Discharge suction bypass
Heat exchanger capacity control
Control box internal temperature
Liquid pipe temperature
Thermistor
Discharge pipe temperature
ACC inlet pipe temperature
OA
temperature
IGBT
temperature
Function setting connector
Power supply
Indoor/Outdoor transmission cable
Central control transmission cable
Terminal block
Heat exchanger inlet pipe temperature
For opening/closing the bypass circuit
Heat exchanger low pressure bypass
For opening/closing the bypass circuit
*1.Single-dotted lines indicate wiring not supplied with the unit.
*2.Dot-dash lines indicate the control box boundaries.
*3.Refer to the Data book for connecting input/output signal connectors.
*4.Daisy-chain terminals (TB3) on the outdoor units in the
same refrigerant system together
.
*5.Faston terminals have a locking function.
Make sure the terminals are securely locked
in place after insertion. Press the tab
on the terminals to removed them.
*6.Control box houses high-voltage parts.
Before inspecting the inside of the
control box,turn of
f the power
,keep
the unit of
f for at least 10 minutes,
and confirm that the voltage between
FT
-P
and FT
-N on INV Board has dropped
to DC20V or less.
*7.Dif
ference of appliance
Model name
Appliance
P72
*7 do not exist
P96/P120
*7 exist
+
-
+
+
+
+
+
+
+
+
+
2
1
t°
t°
t°
t°
t°
t°
t°
Содержание PURY-P120Y(T)HMU-A
Страница 1: ......
Страница 11: ... 2 ...
Страница 25: ... 16 ...
Страница 65: ... 56 ...
Страница 88: ... III Outdoor Unit Components 79 HWE0803A GB 2 RELAY BOARD RELAY 4 board 3 RELAY BOARD RELAY 10 board ...
Страница 89: ... 80 ...
Страница 91: ... 82 ...
Страница 99: ... 90 ...
Страница 101: ... 92 ...
Страница 115: ... 106 ...
Страница 116: ... 107 HWE0803A GB VI Refrigerant Circuit 1 Refrigerant Circuit Diagram 109 2 Principal Parts and Functions 116 ...
Страница 117: ... 108 ...
Страница 133: ... 124 ...
Страница 161: ... 152 ...
Страница 163: ... 154 ...
Страница 187: ... 178 ...
Страница 340: ... 331 HWE0803A GB X LED Monitor Display on the Outdoor Unit Board 1 How to Read the LED on the Service Monitor 333 ...
Страница 341: ... 332 ...
Страница 387: ......