APPX
Appendix 2 Remote Register
229
A
■
Remote register (RWw)
*1 The area is used for the system.
Device number
Name
CC-Link IE TSN Network synchronous communication function
Not used
Synchronous X/Y control
mode
Synchronization cycle
timing control mode
Set time synchronization
control mode
RWw0
Module operation area
Module operation area
Module operation area
Module operation area
RWw1
Use prohibited
Use prohibited
Use prohibited
Use prohibited
RWw2
Function selection setting area
Function selection setting area
Function selection setting area
Function selection setting area
RWw3
Use prohibited
Use prohibited
Use prohibited
Use prohibited
RWw4
Use prohibited
Use prohibited
Use prohibited
ON/OFF selection flag X0 to X7,
Y8 to YF
RWw5 to RWwB
Use prohibited
Use prohibited
Use prohibited
Use prohibited
RWwC
Output Y ON information clear
request Y8 to YF
Output Y ON information clear
request Y8 to YF
Output Y ON information clear
request Y8 to YF
Output Y ON information clear
request Y8 to YF
RWwD
Use prohibited
Use prohibited
Use prohibited
Use prohibited
RWwE
Output Y OFF information clear
request Y8 to YF
Output Y OFF information clear
request Y8 to YF
Output Y OFF information clear
request Y8 to YF
Output Y OFF information clear
request Y8 to YF
RWwF to RWw2F
Use prohibited
Use prohibited
Use prohibited
Use prohibited
RWw30, RWw31
Use prohibited
Use prohibited
Synchronization output timing
setting Y8 OFF to ON
Output time setting Y8
RWw32, RWw33
Use prohibited
Use prohibited
Synchronization output timing
setting Y8 ON to OFF
RWw4C, RWw4D
Use prohibited
Use prohibited
Synchronization output timing
setting YF OFF to ON
Output time setting YF
RWw4E, RWw4F
Use prohibited
Use prohibited
Synchronization output timing
setting YF ON to OFF