Parameter
Operation
MELSERVO J2-Super
4 - 13
Set the parameter value and switch power off once, then switch it on again to make that
parameter setting valid.
The values corresponds with the factory settings of the servo amplifier. Connecting it with
the servo system controller and switching power on changes them to the settings of the
servo system controller.
Setting and changing cannot be made from the peripheral software of the motion controller.
Function
No. Symbol
Name
Initial value
Unit
Customer
setting
Expansion
parameters
27
MO1
Analog output 1 offset
0
mV
28
MO2
Analog output 2 offset
0
mV
29
—
Reserved
0001
—
30
ZSP
Zero speed
50
r/min
31
ERZ
Error excessive alarm level
80
0.1 × r
32
OP5
Function selection 5
0000
—
33
OP6
Function selection 6
0000
—
34
VPI
PI-/PID control switch-over position
droop
0
Pulse
35
—
Reserved
0
—
36
VDC
Speed differential compensation
980
—
37
—
Reserved
0010
—
38
ENR
Encoder output pulses
4000
Pulse/r
39
—
Reserved
0
—
40
BLK
Parameter entry prohibition
0000
—
Tab. 4-12:
Parameter overview (2)
Содержание MELSERVO MRJ2S-B
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 14: ...VIII ...
Страница 18: ...Contents XII ...
Страница 48: ...Introduction System configuration 1 30 ...
Страница 58: ...Installation General environmental conditions 2 10 ...
Страница 86: ...Connection Station number setting 3 28 ...
Страница 122: ...Operation Gain 4 36 ...
Страница 134: ...Absolute position detection system General description 6 6 ...
Страница 146: ...Accessories Special accessories 7 12 ...
Страница 148: ...Maintenance and Inspection Life 8 2 ...
Страница 174: ...Specifications Standard specifications 10 16 ...
Страница 176: ...EMC Directives Requirements 11 2 ...
Страница 198: ...Index iv ...
Страница 199: ......