Troubleshooting
Alarms and Warnings
9 - 6
Display
Error
Definition
Cause
Action
32
Overcurrent
Current that flew is
higher than the
permissible current
of the servo
amplifier.
1. Short occurred in servo amplifier
output phases U, V and W.
Correct the wiring
2. Transistor of the servo amplifier
faulty.
Checking method: Alarm (32) occurs if
power is switched on after U, V and W
are disconnected.
Change the servo
amplifier
3. Low impedance ground fault
occurred in servo amplifier output
phases U, V and W.
Eliminate earth fault
4. External noise caused the
overcurrent detection circuit to
misoperate.
Take noise
suppression
measures.
33
Overvoltage
Converter bus
voltage exceeded
400V (servo
amplifier 200V) and
800V (servo
amplifier 400V)
respecively.
1. Lead of built-in regenerative brake
resistor or regenerative brake option is
open or disconnected.
1. Change lead
2. Connect
correctly
2. Regenerative transistor faulty
Change servo
amplifier
3. Wire breakage of built-in
regenerative brake resistor or
regenerative brake option
1. Change servo
amplifier
2. Change
regenerative brake
option
4. The regenerative transistor is
broken.
Change servo
amplifier
5. Power supply voltage high
Connect the units to
the correct power
supply
34
CRC error
Bus cable is faulty.
1. Bus cable disconnected
Connect bus cable
correctly
2. Bus cable fault
Change the bus
cable
3. Noise entered bus cable
Ensure correct
cable laying and
screening
4. Termination connector disconnected Connect
termination
connector
5. The same No. exists in the servo
amplifier side station setting
Set station number
correctly
35
Command
frequency error
Input frequency of
command pulse is
too high.
1. Command given is greater than the
maximum speed of the servo motor
Review operation
program.
2. Noise entered bus cable
Ensure correct
cable laying and
screening
3. Servo system controller failure
Change the servo
system controller
36
Transfer error
Bus cable or printed
board is faulty
1. Bus cable is disconnected.
Connect the
connector of the
bus cable
2. Bus cable fault
Change the bus
cable
3. Printed board is faulty
Change the servo
amplifier
4. Termination connector
disconnected
Connect
termination
connector
Tab. 9-2:
Failure corrective action (3)
Содержание MELSERVO MRJ2S-B
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 14: ...VIII ...
Страница 18: ...Contents XII ...
Страница 48: ...Introduction System configuration 1 30 ...
Страница 58: ...Installation General environmental conditions 2 10 ...
Страница 86: ...Connection Station number setting 3 28 ...
Страница 122: ...Operation Gain 4 36 ...
Страница 134: ...Absolute position detection system General description 6 6 ...
Страница 146: ...Accessories Special accessories 7 12 ...
Страница 148: ...Maintenance and Inspection Life 8 2 ...
Страница 174: ...Specifications Standard specifications 10 16 ...
Страница 176: ...EMC Directives Requirements 11 2 ...
Страница 198: ...Index iv ...
Страница 199: ......