General environmental conditions
Installation
MELSERVO J2-Super
2 - 1
2
Installation
2.1
General environmental conditions
b
CAUTION:
●
The equipment must be installed in the specified direction. Otherwise, a fault may
occur.
●
Leave specified clearances between the servo amplifier and control box inside
walls or other equipment.
Environmental conditions
Data
Servo amplifier
Servo motor
Ambient temperature during operation 0 to
+
55°C (non-freezing)
0 to
+
40°C (non-freezing)
Ambient humidity during operation
Max. 90% (no condensation)
Max. 80% (no condensation)
Ambient temperature in storage
−
20 to
+
65°C
−
15 to
+
70°C
Ambient humidity in storage
Max. 90% (no condensation)
Max. 90% (no condensation)
Ambience
Indoors (no direct sunlight); no corrosive gas, no inflammable gas, no oil
mist, no dust)
Altitude above sea level
Max. 1000m
Protective structure
IP00
HC-KFS/MFS: IP55,
HC-SFS/RFS: IP65
Vibration
Max. 5.9m/s² (0,6 g)
Tab. 2-1:
Environmental condition overview
Содержание MELSERVO MRJ2S-B
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 14: ...VIII ...
Страница 18: ...Contents XII ...
Страница 48: ...Introduction System configuration 1 30 ...
Страница 58: ...Installation General environmental conditions 2 10 ...
Страница 86: ...Connection Station number setting 3 28 ...
Страница 122: ...Operation Gain 4 36 ...
Страница 134: ...Absolute position detection system General description 6 6 ...
Страница 146: ...Accessories Special accessories 7 12 ...
Страница 148: ...Maintenance and Inspection Life 8 2 ...
Страница 174: ...Specifications Standard specifications 10 16 ...
Страница 176: ...EMC Directives Requirements 11 2 ...
Страница 198: ...Index iv ...
Страница 199: ......