System configuration
Introduction
MELSERVO J2-Super
1 - 27
1.7.2
Servo amplifier 400V
System configuration for MR-J2S-200B4 or less
S001252C
Fig. 1-30:
Overview of the system configuration for MR-J2S-200B4 or less
NOTE
A listing of options and auxillary equipment can be find in Tab. 1-12 on page 1-29.
+
-
Power supply
No-fuse
circuit breaker
Magnetic
contactor
L1, L2, L3
Regenerative
brake option
P, C
CN4
Personal computer
Serco system
controller
or
preceding
axis servo
amplifier
CN1A
Servo amplifier
CN1B
CN3
Subsequent
axis servo
amplifier
or
termination
connector
Circuit protector
Power
supply
24VDC
CN2
Protective earth terminal
Encoder cable
Servo motor
power supply
Servo motor