Gain
Operation
MELSERVO J2-Super
4 - 35
Auto tuning selection
The MR-J2-Super series has an addition of the load inertia moment ratio fixing mode. It also has
the addition of the manual mode 1 which permits manual adjustment with three parameters.
S000989C
Fig. 4-11:
Auto tuning selection (parameter No. 9)
Gain adjustment mode
Auto tuning selection
Description
MR-J2
MR-J2-Super
Interpolation mode
0
0
Position control gain 1 (PG1) is
fixed
Auto tuning
Auto tuning 1
1
1
For speed and position control
Auto tuning 2
—
3
No estimation of load inertia
moment ratio,
Response level setting valid
Auto tuning
invalid
Manual mode 1
—
4
Simple manual adjustment
Manual mode 2
2
2
Manual adjustment of all gains
Tab. 4-24:
Auto tuning comparison
0
0
0
1
Auto tuning selection