218
13 PROGRAMMING
13.3 When the Module Is Connected to a Head Module
User devices
Device
Description
M100
Setting start command
M110
Hardware logic control start command
M111
Hardware logic control stop command
M112
Count value read command
M113
Operating condition batch-reset command
M114
Hardware logic control stop flag clear command at disconnection
M120
Error reset command
M200, M201
Write complete flag
M210, M211
Read complete flag 1
M220, M221
Read complete flag 2
M300
Count value reading flag
M310
Number of writes to a flash ROM reading flag
M1000
Communication ready flag (station number 1)
M1001
Setting request at a startup
M1002
Setting request signal
M1003
Setting complete flag at a startup
D100 (W1010)
Storing the latest error code
D200, D201
Storing the cumulative number of write accesses to a flash ROM
D1000
Storing the clear setting of error history
D1010, D1011
Count value
F200
Parameter write complete with an error
F210
Count value read complete with an error
F220
Number of writes to a flash ROM read complete with an error