9 CREATING A HARDWARE LOGIC
9.1 Main Blocks in the Hardware Logic Outline Window
115
9
Parameter
The following table shows the parameters of the SSI encoder block.
Variable name
Data type
Valid range
Default value
Description
Encoder Type
Word
Single Turn
Multi Turn
Single Turn
Set the type of the SSI encoder.
• Single Turn
• Multi Turn
Transmission Speed
Word
100KHz
200KHz
300KHz
400KHz
500KHz
1.0MHz
1.5MHz
2.0MHz
100KHz
Set the frequency of the clock signal to perform
synchronous data communication with the SSI
encoder.
Monoflop Time
Word
10 to 10000 (
μ
s)
10 (
μ
s)
Indicates the time until the next communication is
ready to start after the output of the last clock signal.
Set the monoflop time according to the specifications of
the SSI encoder to be connected.
For details on the monoflop time, refer to the following.
Signal Error Detection
Word
Disable
Enable
Disable
Set whether to detect an error (disconnection, short-
circuit) of the data signal wire externally connected to
the SSI encoder.
• Error detection disabled: Disable
• Error detection enabled: Enable
For details on the signal error detection, refer to the
following.
Page 121 Signal error detection
Direction
Word
Forward
Reverse
Forward
The counting direction of received data from the SSI
encoder can be changed by setting this item.
• Forward
• Reverse
For details on the counting direction setting, refer to the
following.
Page 120 Counting direction setting
Data Frame Setting
Click the [Detail] button to open the "Data Frame
Setting" window in which the details of a data frame
can be set.
Содержание MELSEC-L Series LD40PD01