981
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
B Instruction Execution Time
B-5 Execution Time of Pulse Generation Instruction P in Each Applied Instruction
31
FN
C
275-
FN
C
279
Da
ta
Transf
er 3
32
FN
C
280-
FN
C
289
H
igh Speed
Pr
ocessing 2
33
FN
C
29
0-F
N
C
299
Ext
ens
ion Fi
le
R
egi
ster
34
FN
C
300-
FN
C
305
FX
3U
-C
F-A
D
P
35
SFC•S
TL
Pr
ogr
am
m
ing
36
In
ter
rupt
Functi
on
37
Special D
evice
38
E
rro
r C
ode
A
Ve
rs
ion U
p
In
fo
rm
atio
n
B
Execution T
im
es
• FX
3G
PLCs (Extension mode)
Applied instruction
Execution time
Remarks
MOV instruction (FNC 12)
Execution time at rising edge of input: Execution time in ON status = 5.43
µ
s
Non-execution time: Execution time in OFF status = 0.81
µ
s
BCD instruction (FNC 18)
Execution time at rising edge of input: Execution time in ON status = 5.42
µ
s
Non-execution time: Execution time in OFF status = 0.81
µ
s
BIN instruction (FNC 19)
Execution time at rising edge of input: Execution time in ON status = 5.21
µ
s
Non-execution time: Execution time in OFF status = 0.81
µ
s
ADD instruction (FNC 20)
Execution time at rising edge of input: Execution time in ON status = 6.68
µ
s
Non-execution time: Execution time in OFF status = 0.81
µ
s
SUB instruction (FNC 21)
Execution time at rising edge of input: Execution time in ON status = 6.78
µ
s
Non-execution time: Execution time in OFF status = 0.81
µ
s
MUL instruction (FNC 22)
Execution time at rising edge of input: Execution time in ON status = 7.24
µ
s
Non-execution time: Execution time in OFF status = 0.81
µ
s
DIV instruction (FNC 23)
Execution time at rising edge of input: Execution time in ON status = 7.44
µ
s
Non-execution time: Execution time in OFF status = 0.81
µ
s
INC instruction (FNC 24)
Execution time at rising edge of input: Execution time in ON status = 3.49
µ
s
Non-execution time: Execution time in OFF status = 0.81
µ
s
DEC instruction (FNC 25)
Execution time at rising edge of input: Execution time in ON status = 3.49
µ
s
Non-execution time: Execution time in OFF status = 0.81
µ
s
WAND instruction (FNC 26)
Execution time at rising edge of input: Execution time in ON status = 6.81
µ
s
Non-execution time: Execution time in OFF status = 0.81
µ
s
WOR instruction (FNC 27)
Execution time at rising edge of input: Execution time in ON status = 6.81
µ
s
Non-execution time: Execution time in OFF status = 0.81
µ
s
WXOR instruction (FNC 28)
Execution time at rising edge of input: Execution time in ON status = 6.81
µ
s
Non-execution time: Execution time in OFF status = 0.81
µ
s
Other applied instructions
Execution time at rising edge of input: Execution time in ON 0.7
µ
s
Non-execution time: Execution time in OFF 0.6
µ
s