![Mitsubishi Electric MELSEC FX3G Скачать руководство пользователя страница 928](http://html.mh-extra.com/html/mitsubishi-electric/melsec-fx3g/melsec-fx3g_programming-manual_239083928.webp)
926
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
37 Operation of Special Devices (M8000 -, D8000 -)
37.2 Supplement of Special Devices (M8000 - and D8000 -)
• FX
3G
PLCs
*1.
Only a 40-point or 60-point type FX
3G
PLC can be connected.
Number
Operation and function
FX
3U
-4AD-ADP
FX
3U
-4DA-ADP
FX
3U
-3A-ADP
Applicable
version
Ver.1.00 or later
Ver.1.00 or later
Ver.1.20 or later
1st analog special adapter
M 8280
Input mode switching Ch1
Output mode switching Ch1
Input mode switching Ch1
M 8281
Input mode switching Ch2
Output mode switching Ch2
Input mode switching Ch2
M 8282
Input mode switching Ch3
Output mode switching Ch3
Output mode switching
M 8283
Input mode switching Ch4
Output mode switching Ch4
Not used
M 8284
Not used
Output hold mode cancel Ch1 Not used
M 8285
Not used
Output hold mode cancel Ch2 Not used
M 8286
Not used
Output hold mode cancel Ch3 Output hold mode cancel
M 8287
Not used
Output hold mode cancel Ch4 Sets whether or not input channel 1 is used.
M 8288
Not used
Not used
Sets whether or not input channel 2 is used.
M 8289
Not used
Not used
Sets whether or not output channel is used.
2nd analog special adapter
*1
M 8290
Input mode switching Ch1
Output mode switching Ch1
Input mode switching Ch1
M 8291
Input mode switching Ch2
Output mode switching Ch2
Input mode switching Ch2
M 8292
Input mode switching Ch3
Output mode switching Ch3
Output mode switching
M 8293
Input mode switching Ch4
Output mode switching Ch4
Not used
M 8294
Not used
Output hold mode cancel Ch1 Not used
M 8295
Not used
Output hold mode cancel Ch2 Not used
M 8296
Not used
Output hold mode cancel Ch3 Output hold mode cancel
M 8297
Not used
Output hold mode cancel Ch4 Sets whether or not input channel 1 is used.
M 8298
Not used
Not used
Sets whether or not input channel 2 is used.
M 8299
Not used
Not used
Sets whether or not output channel is used.