2 Overview (Sequence Program)
2.7 Types and Setting of Parameters
5
Assigning I/Os, setting the initial values for special units, and setting built-in
CC-Link/LT
1. Click the "I/O assignment" tab, and then set the I/O assignment, special function block/unit
names and built-in CC-Link/LT.
In order to use the "Special Unit" field, the "Special Function Block Settings" box in the
"Memory capacity" tab must be checked first.
When setting the station information in "Built-in CC-Link/LT Setup", it is necessary to put a
check mark to "Built-in CC-Link/LT Setup" on the "Memory capacity" tab.
*1.
This area can be set only in FX
3U
/FX
3UC
PLCs.
*2.
This item can be set only in the FX
3UC
-32MT-LT-2.
Set item
Contents of setting
Setting range
I/O
Input relay
When the I/O range is set here according to the system configuration,
those inputs and outputs are checked in programming by GX Developer.
FX
3U
/FX
3UC
:
0 to 377
FX
3G
:
0 to 177
Output relay
FX
3U
/FX
3UC
:
0 to 377
FX
3G
:
0 to 177
Special Unit
*1
(It is
necessary
to set the
memory
capacity.)
Unit No.
This is the unit number of each special function block/unit.
–
Unit Name
Set the name of each special function block/unit whose initial values are
to be set.
32 half-width
characters
(or 16 full-width
characters)
Up
This button moves the cursor to the upper line (transposes the upper line).
–
Down
This button moves the cursor to the lower line (transposes the lower line).
–
Set...
This button displays "Special Function Block Settings" dialog box of the
selected unit number.
→
Refer to the next page.
–
Delete
This button deletes the setting of the selected unit number.
–
Delete All
This button deletes all existing setting in "Special Unit" field.
–
Read PLC data This button reads "Special Unit" field from the connected PLC.
–
Built-in
CC-Link/LT
Setup
*2
Set...
This button displays the "Built-in CC-Link/LT Setup" dialog box.
–
This example shows a window in an
FX
3U
/FX
3UC
PLC.