949
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-1 Programming Tool Applicability
31
FN
C
275-
FN
C
279
Da
ta
Transf
er 3
32
FN
C
280-
FN
C
289
H
igh Speed
Pr
ocessing 2
33
FN
C
29
0-F
N
C
299
Ext
ens
ion Fi
le
R
egi
ster
34
FN
C
300-
FN
C
305
FX
3U
-C
F-A
D
P
35
SFC•S
TL
Pr
ogr
am
m
ing
36
In
ter
rupt
Functi
on
37
Special D
evice
38
E
rro
r C
ode
A
Ve
rs
ion U
p
In
fo
rm
atio
n
B
Execution T
im
es
2) FX-30P
FX-30P is applicable to FX
3G
, FX
3U
and FX
3UC
PLCs starting with the following version:
a) FX
3G
PLCs
b) FX
3U
PLCs
c) FX
3UC
PLCs
2. In the case of programming tool (version) not applicable to FX
3G
, FX
3U
and FX
3UC
PLCs
(using an alternative model)
Even using a programming tool not applicable to the FX
3G
, FX
3U
and FX
3UC
PLCs, programming is enabled
when an alternative model is set.
In this case, however, programming is enabled only in the function ranges such as instructions, device ranges
and program sizes available in a PLC selected as the alternative model. Use a programming tool which can
select the model (FX3G, FX3U(C) or FX3UC) to change parameters such as memory capacity and file
register capacity.
Use a programming tool which can select "FX3G" to perform communication using the standard USB port
built in FX
3G
PLCs..
*1.
For Ver. 8.13P to 8.24A of GX Developer, the PLC type is FX3UC.
*2.
"FX
2N
" is selected when the FX-10P(-E) is used.
3. Program transfer speed and programming tool
When any of the following interfaces are used for GX Developer (Ver.8.13P or later), reading and writing of
programs and monitoring of devices can be executed at high speed (115.2 kbps) in the FX
3U
and FX
3UC
PLCs.
FX-30P can be executed at high speed (115.2kbps) in FX
3U
, FX
3UC
PLCs.
• Standard built-in port or expansion board FX
3U
-422-BD for RS-422
When the RS-232C/RS-422 converter FX-232AWC-H or USB/RS-422 converter FX-USB-AW is connected
• Expansion board FX
3U
-232-BD for RS-232C
• Special adapter FX
3U
-232ADP(-MB) for RS-232C
• Expansion board FX
3U
-USB-BD for USB
When any of the following interfaces are used for GX Developer (Ver.8.72A or later), reading and writing of
programs and monitoring of devices can be executed at high speed (115.2 kbps) in the FX
3G
PLCs.
FX-30P can be executed at high speed (115.2kbps) in FX
3G
PLCs.
• Standard built-in port (RS-422) or expansion board FX
3G
-422-BD for RS-422
When the RS-232C/RS-422 converter FX-232AWC-H is connected
• Expansion board FX
3G
-232-BD for RS-232C
• Special adapter FX
3U
-232ADP(-MB) for RS-232C
In earlier programming software, the communication speed is 9,600 or 19,200 bps.
In GX Developer, the communication speed can be set using the following procedure:
Select "Online"
→
"Transfer setup..."
→
"PC side I/F", and double-click the "Serial" icon.
FX
3G
PLC
version
Model name
Applicable FX-30P version
Remarks
Ver. 1.00 or later FX-30P
Ver.1.00 or later
FX
3U
PLC
version
Model name
Applicable FX-30P version
Remarks
Ver. 2.20 or later
FX-30P
Ver.1.00 or later
Ver. 2.61 or later
Not applicable
Available for FX
3U
PLCs prior to
Ver. 2.61
FX
3UC
PLC
version
Model name
Applicable FX-30P version
Remarks
Ver. 1.00 or later
FX-30P
Ver.1.00 or later
Ver. 2.61 or later
Not applicable
Available for FX
3UC
PLCs prior to
Ver. 2.61
Model to be
programmed
Model to be set
Priority High
→
Low
FX
3G
PLC
FX
3G
→
FX
1N
*4
→
FX
2N
*2
→
FX
2
FX
3U
PLC
FX
3U(C)
*1
→
FX
3UC
→
FX
2N
→
FX
2
FX
3UC
PLC
FX
3U(C)
*1
→
FX
3UC
→
FX
2N
→
FX
2