![Mitsubishi Electric MELSEC FX3G Скачать руководство пользователя страница 582](http://html.mh-extra.com/html/mitsubishi-electric/melsec-fx3g/melsec-fx3g_programming-manual_239083582.webp)
580
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
20 Positioning Control – FNC150 to FNC159
20.6 FNC157 – PLSV / Variable Speed Pulse Output
20.6
FNC157 – PLSV / Variable Speed Pulse Output
Outline
This instruction outputs variable speed pulses with an assigned rotation direction.
→
For explanation of the instruction, refer to the Positioning Control Edition manual.
→
For cautions on using special high speed output adapters,
refer to the Positioning Control Edition manual.
1. Instruction format
2. Set data
*1.
Setting range:
−
32768 to
−
1, +1 to +32767 (except 0) Hz for 16-bit operation
Following range for 32-bit operation
3. Applicable devices
S
1 : Specify Y000, Y001 or Y002
*1
transistor output from the main unit, or specify Y000, Y001, Y002
*3
or
Y003
*3
from a high-speed output special adapter
*2
.
*1.
Y002 is not available in 14-point and 24-point type FX
3G
PLC.
*2.
High-speed output special adapters can be connected only to FX
3U
PLC.
*3.
To use Y002 or Y003 with a high-speed output special adapter, connected a second high-speed
output special adapter.
Points
• When using a relay output type FX
3U
PLC, a special high speed output adapter is required.
• Outputs of special high speed output adapters work as differential line drivers.
Operand type
Description
Data type
Device number for output pulse frequency
*1
16- or 32-bit binary
Device number (Y) from which pulses are to be output
Bit
Device number to which rotation direction signal is output
Pulse output destination
Setting range
FX
3U
PLC
Special high speed output adapter
−
200,000 to
−
1, +1 to 200,000 (Hz)
FX
3G
/FX
3U
/FX
3UC
PLC Main unit (transistor output)
−
100,000 to
−
1, +1 to 100,000 (Hz)
Oper-
and
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
X Y M T C S D
.b KnX KnY KnM KnS T C D R U
\G
V Z Modify K H
E
"
"
P
3
3
3
3
3 3 3 3
S
4
3 3
3
3 3
S
1
3
S
2
3
3
S
3
3
FNC 157
PLSV
D
PLSV
16-bit Instruction
9 steps
Mnemonic
Operation Condition
Continuous
Operation
DPLSV
32-bit Instruction
17 steps
Mnemonic
Operation Condition
Continuous
Operation
S
1
D
1
D
2
S
1
D
1
D
2