Maintenance and inspection procedures 5-117
9) After adjustment fastens the fixing nut of tension adjustment screw <3>, and certainly fixes tension
adjustment screw <3>. Moreover, also fasten the three
motor plate fixing screws
<1> certainly (M4 screw:
tightening torque is 4.51Nm). Improper tightening can cause the belt to loosen with vibration.
10) Install the No. 2 arm cover R securely as before.
11) Refer to
Page 150, "5.6 Resetting the origin"
, and reset the origin position.
12) When the maintenance forecast function is valid, reset the accumulation data about the belt. Reset by the
dedicated screen or parameter MFBRST of RT ToolBox3. Refer to "RT ToolBox3/RT ToolBox3 mini User's
Manual" for operation of RT3 and refer to "Instruction Manual/Detailed Explanation of Functions and
Operations" for the parameter.