3-70
Installing the solenoid valve set
3Installing the option devices
4) Cut the φ4 secondary piping air hoses.
(only internal wiring and piping specification)
Cutting the φ4 secondary piping air hoses facilitates connection to the solenoid valve.
Securely cut and connect the air hose to a surely suitable length.
Failure to observe this could lead to the air hose breaks within an arm, and a
solenoid valve becomes the cause of not operating to a normality.
・ Align the φ4 secondary piping air hoses from No.1 to No.4 on the No.2 arm cover side as shown in the
figure.
・ Apply the scale to the arm lower end on the No.2 arm cover L side, and measure the length, then mark
and cut the hose.
・ Cut the air hose vertically in the lengthwise direction of the air hose with a dedicated cutter. If the cut
end is not vertical, it causes air leakage.
CAUTION
1
2
3
4
<Cutting dimension guide>
1: 50-55mm
2: 45-50mm
3: 40-45mm
4: 35-40mm
Take sufficient care to prevent for
-
eign matters (cut chips of air hoses,
etc.) from entering the robot.
CAUTION
Enlarge
Scale
Arm lower end
Air hose
Mark
C
u
tt
in
g
di
m
e
n
si
o
n