5-144
Maintenance and inspection procedures
(1) Replacing the battery of the robot arm
The battery circuit board connection cable is used to supply power from the backup
battery to the encoder. The cable must be connected while replacing the battery or
operating usually. Thus, if the cable connection is incomplete, the encoder position
data will be lost, and resetting the origin is necessary.
Before replacing the backup battery, check that the capacitor is fully charged.
If the robot has been used for over 36,000 hours, the battery life is gradually short
-
ened due to deterioration of the capacitor.
Replace the battery one by one . If all batterys are removed the encoder data will be
lost, and resetting the origin is necessary.
The battery installation position is shown below. Refers to the figure and replaces the batteries in the following
procedures.
■ RV-2FR series
Fig.5-30 : Replacing the battery (RV-2FR series)
1) Turn the controller control power OFF.
2) Remove the battery cover, referring to
Page 100, "5.3.2 Installing/removing the cover"
3) Check that the capacitor is fully charged. Press the button on the DQ006 circuit board and check that the
LED on the same circuit board turns on.
Replace the battery within 15 minutes after checking that the LED turns on.
If the LED does not turn on when the button is pressed, the capacitor needs to be charged. Turn on the
controller and charge the capacitor for approximately 30 minutes.
4) Replaces the backup battery one by one. The battery holder is located inside the battery cover. Remove the
old battery from the holder, and disconnect the lead connector.
5) Insert the new battery into the holder, and connect the lead connector. Replace all batteries with new ones
at the same time.
CAUTION
CAUTION
CAUTION
㻮㼍㼠㼠㼑㼞㼥
㻮㼍㼠㼠㼑㼞㼥㻌㼔㼛㼘㼐㼑㼞
㻰㻽㻜㻜㻢㻌
㼏㼕㼞㼏㼡㼕㼠㻌㼎㼛㼍㼞㼐
㻮㼍㼠㼠㼑㼞㼥㻌㼏㼛㼢㼑㼞
㻮㼕㼚㼐㻌㼟㼏㼞㼑㼣㻌㻔㻠㻕
㻰㼑㼠㼍㼕㼘㼟㻌㼒㼛㼞㻌㻰㻽㻜㻜㻢㻌㼏㼕㼞㼏㼡㼕㼠㻌㼎㼛㼍㼞㼐
㻮㼍㼠㼠㼑㼞㼥㻌㼏㼕㼞㼏㼡㼕㼠㻌㼎㼛㼍㼞㼐㻌㼏㼛㼚㼚㼑㼏㼠㼕㼛㼚㼏㼍㼎㼘㼑
㻰㼛㻌㼚㼛㼠㻌㼐㼕㼟㼏㼛㼚㼚㼑㼏㼠㻚
㻸㻱㻰
㻮㼡㼠㼠㼛㼚
㻸㼑㼍㼐㻌㼏㼛㼚㼚㼑㼏㼠㼛㼞