62
List of alarm display
5 TROUBLESHOOTING
When an alarm occurs in the inverter, the protective function is activated bringing the inverter to an alarm stop and
the PU display automatically changes to any of the following error (alarm) indications.
If your fault does not correspond to any of the following errors or if you have any other problem, please contact your
sales representative.
•
Retention of alarm output signal ..................When the magnetic contactor (MC) provided on the input side of the
inverter is opened at the activation of the protective function, the inverter's
control power will be lost and the alarm output will not be held.
•
Alarm display ............................................When the protective function is activated, the operation panel display
automatically switches to the above indication.
•
Resetting method............................................When the protective function is activated, the inverter output is kept stopped.
Unless reset, therefore, the inverter cannot restart.
(Refer to page 74.)
•
When the protective function is activated, take the corresponding corrective action, then reset the inverter, and
resume operation.
5.1 List of alarm display
* If an error occurs when using the FR-PU04, "Fault 14" is displayed
on the FR-PU04.
Operation Panel
Indication
Name
Refer
to
E
rro
r me
s
s
a
g
e
HOLD
Operation panel lock
63
Er1 to 4
Parameter write error
63
rE1 to 4
Copy operation error
63
Err.
Error
64
Wa
rn
in
g
s
OL
Stall Prevention (overcurrent)
65
oL
Stall prevention (overvoltage)
65
RB
Regenerative brake prealarm
66
TH
Electronic thermal relay
function prealarm
66
PS
PU Stop
65
MT
Maintenance signal output
66
CP
Parameter copy
66
M
inor
f
a
u
lt
FN
Fan fault
66
Ma
jo
r f
a
ilu
re
s
E.OC1
Overcurrent shut-off
during acceleration
67
E.OC2
Overcurrent shut-off
during constant speed
67
E.OC3
Overcurrent shut-off during
deceleration or stop
67
E.OV1
Regenerative overvoltage
shut-off during acceleration
67
E.OV2
Regenerative overvoltage
shut-off during constant
speed
68
E.OV3
Regenerative overvoltage
shut-off during
deceleration or stop
68
E.THT
Inverter overload shut-off
(electronic thermal relay function)
68
E.THM
Motor overload shut-off
(electronic thermal relay function)
68
E.FIN
Fin overheat
69
E.IPF
Instantaneous power
failure protection
69
E.UVT
Undervoltage protection
69
to
to
Ma
jo
r fa
ilu
re
s
E.ILF*
Input phase failure
69
E.OLT
Stall Prevention
70
E.GF
Output side ground fault
overcurrent protection
70
E.LF
Output phase failure
protection
70
E.OHT
External thermal relay
operation
*2
70
E.PTC*
PTC thermistor operation
70
E.OPT
Option alarm
70
E.OP1
Option slot alarm
71
E. 1
Option alarm
71
E.PE
Parameter storage devide
alarm
71
E.PUE
PU disconnection
71
E.RET
Retry count excess
71
E.PE2*
Parameter storage devide
alarm
71
/
/
E. 6 /
E. 7 /
E.CPU
CPU error
72
E.CTE
Operation panel power
supply short circuit
RS-485 terminals power
supply short circuit
72
E.P24
24VDC power output short
circuit
72
E.CDO*
Output current detection
value exceeded
72
E.IOH*
Inrush resistor overheat
72
E.SER*
Communication error
(inverter)
73
E.AIE*
Analog input error
73
E.BE
Brake transistor alarm
detection
69
E.13*
Internal circuit error
73
Operation Panel
Indication
Name
Refer
to
Содержание FR-F700 Series
Страница 134: ...MEMO ...