101
List of parameters classified by purpose of use
Operation selection at power
failure and instantaneous
power failure
Restart operation after instantaneous power failure
Pr. 57, Pr. 58, Pr. 162 to Pr. 165,
Pr. 299, Pr. 611
Decelerate the motor to a stop at instantaneous power failure
Pr. 261 to Pr. 266
Operation setting at alarm
occurrence
Retry function at alarm occurrence
Pr. 65, Pr. 67 to Pr. 69
Output function of alarm code
Pr. 76
Input/output phase failure protection selection
Pr. 251, Pr. 872
Regeneration avoidance function
Pr. 882 to Pr. 886
Energy saving operation
Energy saving control selection
Pr. 60
How much energy can be saved (energy saving monitor)
Pr. 891 to Pr. 899
Reduction of the motor noise
Measures against noise and
leakage currents
Carrier frequency and SoftPWM selection
Pr. 72, Pr. 240, Pr. 260
Noise elimination at the analog input
Pr. 74
Frequency setting by analog
input
Analog input selection
Pr. 73, Pr. 267, Pr. 573
Override function
Pr. 73, Pr. 252, Pr. 253
Noise elimination at the analog input
Pr. 74
Change of analog input frequency,
adjustment of voltage, current input and frequency
(calibration)
Pr. 125, Pr. 126, Pr. 241,
C2 to C7 (Pr. 902 to Pr. 905)
Compensation at the analog input
Pr. 242, Pr. 243
Misoperation prevention and
parameter setting restriction
Reset selection, disconnected PU detection
Pr. 75
Prevention of parameter rewrite
Pr. 77
Prevention of reverse rotation of the motor
Pr. 78
Display necessary parameters only. (user group)
Pr. 160, Pr. 172 to Pr. 174
Control of parameter write by communication
Pr. 342
Selection of operation mode
and operation location
Operation mode selection
Pr. 79
Operation mode when power is on
Pr. 79, Pr. 340
Operation command source and speed command source
during communication operation
Pr. 338, Pr. 339
Selection of the NET mode operation control source
Pr. 550
Selection of the PU mode operation control source
Pr. 551
Communication operation
and setting
Communication initial setting
Pr. 117 to Pr. 124,
Pr. 331 to Pr. 337, Pr. 341
Control of parameter write by communication
Pr. 342
ModbusRTU communication specifications
Pr. 343
Operation command source and speed command source
during communication operation
Pr. 338, Pr. 339
Selection of the NET mode operation control source
Pr. 550
ModbusRTU protocol (communication protocol selection)
Pr. 549
Special operation and
frequency control
PID control
Pr. 127 to Pr. 134, Pr. 575 to Pr. 577
Switch between the inverter operation and commercial
power-supply operation to use
Pr. 135 to Pr. 139, Pr. 159
Pump function
Pr.575 to Pr.591
Regeneration avoidance function
Pr. 882 to Pr. 886
Useful functions
Free parameter
Pr. 888, Pr. 889
Increase cooling fan life
Pr. 244
To determine the maintenance time of parts.
Pr. 255 to Pr. 259, Pr. 503, Pr. 504
How much energy can be saved (energy saving monitor)
Pr. 60, Pr. 891 to Pr. 899
Setting from the parameter
unit and operation panel
Parameter unit
language switchover
Pr. 145
Operation selection of the operation panel
Pr. 161
Buzzer control of the operation panel
Pr. 990
Contrast adjustment of the parameter unit
Pr. 991
Purpose of Use
Parameter Number
Содержание FR-F700 Series
Страница 134: ...MEMO ...