(E) Environment setting parameters
87
5
GROUP
E
5.2.1
Simple clock function
• When the year, month, day, time and minute are set in
Pr.1006 to Pr.1008
, the converter unit counts the date and time. The
date and time can be checked by reading
Pr.1006 to Pr.1008
.
NOTE
• The clock's count-up data is saved in the converter unit's EEPROM every 10 minutes.
• The clock does not count up while the control circuit power supply is OFF. The clock function must be reset after turning ON
the power supply. Use a separate power supply, such as an external 24 V power supply, for the control circuit of the simple
clock function, and supply power continuously to this control circuit.
• Converter reset is performed if supplying power to the main circuit power supply is started with power supplied only to the
control circuit power supply. Thus, the clock information stored in the EEPROM is restored. Reset at the start of supplying
power to the main circuit can be disabled by setting
Pr.30 Reset selection during power supply to main circuit
. (Refer to
)
• The date set in
Pr.1006 to Pr.1008
is also used for the function in the fault history (refer to
), etc.
The time can be set. The time can only be updated while the converter unit power is ON.
The real time clock function is enabled using an optional LCD operation panel (FR-LU08).
Pr.
Name
Initial
value
Setting range
Description
1006
E020
Clock (year)
2000
2000 to 2099
Set the year.
1007
E021
Clock (month, day)
101
(January 1)
101 to 131, 201 to 228,
(229), 301 to 331,
401 to 430, 501 to 531,
601 to 630, 701 to 731,
801 to 831, 901 to 930,
1001 to 1031, 1101 to 1130,
1201 to 1231
Set the month and day.
1000 and 100 digits: January to December
10 and 1 digits: 1 to the end of month (28, 29,
30 or 31)
For December 31, set "1231".
1008
E022
Clock (hour, minute)
0
(00:00)
0 to 59, 100 to 159,
200 to 259, 300 to 359,
400 to 459, 500 to 559,
600 to 659, 700 to 759,
800 to 859, 900 to 959,
1000 to 1059, 1100 to 1159,
1200 to 1259, 1300 to 1359,
1400 to 1459, 1500 to 1559,
1600 to 1659, 1700 to 1759,
1800 to 1859, 1900 to 1959,
2000 to 2059, 2100 to 2159,
2200 to 2259, 2300 to 2359
Set the hour and minute using the 24-hour
clock.
1000 and 100 digits: 0 to 23 hours
10 and 1 digits: 0 to 59 minutes
For 23:59, set "2359".