34
-
'11 • P
A
C-T
-160
P
C
A
0
0
1
Z
5
4
1
Models FDC200VS,
250VS
RD
POWER SOURCE 3
〜
380
ー
415V 50Hz
/
380V 60Hz
INVERTER
PWB2
DM
RD
N2
P2
P3
BL
BK
GN
-6
RD
+4
R5
AC1
BK
RD
RD
L1o
L1i
TB
BK
BL
WH
RD
RD
N
L3
L2
L1
BR
WH
PWB4
BL
AC3
AC2
52X
DC FAN
CNW1
CNA2
BL
CNO2
CNA1
RD
BL
RD
CNO1
CH
BR
BR
52X
BL
PWB1
BL
WH
WH
BK
BK
E
L3o
L2o
No
L3i
L2i
Ni
GN
CNW
WH
RD
BK
F
(
10A
)
CNW2
BK
BL
POWER WIRES
SIGNAL WIRE
TO INDOOR UNIT
TB
RD
3
1
2
3
1 2
CNFAN2
CNFAN1
CNEEV2
CNEEV1
THo-D
63H1
THo-H
BK
BK
BK
BK
THo-R1
THo-R2
BK
BK
BK
BK
BK
BK
LED2
LED1
OFF
1
3
2
SW3
4
ON
THo-A
THo-S
THo-IPM
RD
RD
Y
BK
Y
BK
LPT
(
WH
)
WH
BK
RD
SW1
OFF
3
SW5
1 2
4
ON
5
6
BR
RD
2
4 3
1
Y
OR
BL
WH
SM1
4
5
6
2
3
BL
BR
RD
Y
OR
1
WH
SM2
FMO2
FMO1
GN
BK
NOISE FILTER
PWB3
t°
t°
t°
t°
t°
t°
20S
BL
BL
BL
CNPS
CNIP
(
Y
)
CNTH
(
WH
)
CNH
CNU
CNB
(
RD
)
(
BL
)
(
BR
)
CNR
CNM
CNS
(
GR
)
(
RD
)
(
WH
)
52X6
52X3
52X1
(
WH
)
(
WH
)
(
RD
)
(
WH
)
(
OR
)
(
BK
)
(
WH
)
(
RD
)
(
RD
)
(
WH
)
(
WH
)
u
Description
52X3
Item
Auxilliary relay
(
for CH
)
52X1
Expansion valve for heating
Current sensor
CT
SM2
Crankcase heater
CH
Fan motor
FM01,02
THo-D
Connector
Terminal block
TB
High pressure switch
63H1
Thermistor
(
Outdoor air temp.
)
THo-A
Compressor motor
CM
Low pressure sensor
LPT
THo-IPM
THo-S
Expansion valve for cooling
SM1
Solenoid valve for 4 way valve
20S
Fuse
F
THo-R1,2
CnA
〜
Z
SW3,5
LED1
SW1
LED2
DM
L
Diode module
Indication lamp
(
GREEN
)
Local setting switch
Pump down switch
Reactor
Auxilliary relay
(
for 20S
)
Thermistor
(
Discharge pipe temp.
)
Thermistor
(
Heat exchanger pipe temp.
)
Thermistor
(
Suction pipe temp.
)
Thermistor
(
IPM
)
Indication lamp
(
RED
)
Color
RD
Mark
Orange
OR
Yellow
/
Green
Y
/
GN
Black
BK
Blue
BL
Gray
GR
Pink
P
Brown
BR
Yellow
Y
White
WH
Red
SW3-3,4
SW3-2
SW3-1
Local setting switch SW3
(
Set up at shipment OFF
)
Snow guard fan control
Defrost control change
Trial operation
becomes below the freezing point.
2
1
3
is finished.
4
SW3-4 is ON.
SW3-3 is ON.
Method of trial operation
Be sure to turn OFF SW3-3 after the trial operation
SW3-4 is OFF, and heating trial operation when
Cooling trial operation will be performed when
Compressor will be in the operation when
Trial operation can be performed by using SW3-3,4.
in a very snowy country, set this switch to ON.
the compressor is not runnning when the unit is used
when outdoor temperature falls to 3 or lower and
fan will run for 30 seconds in every 10 minutes,
When this switch is turned ON, the outdoor unit
turned ON in the area where outside temperature
by turning ON this switch. This switch should be
The defrosting operation interval becomes shorter
200
Model
Power cable, indoor-outdoor connecting wires
MAX over current
Power cable size
(
mm
)
2
(
A
)
Power cable length
(
m
)
indoor-outdoor
wire size x number
(
mm
)
2
Earth wire size
(
mm
)
2
280
19
22
3.5
5.5
21
31
Ø1.6mm x 3
Ø1.6mm
200
Model
At the connection with the duct type indoor unit.
MAX over current
Power cable size
(
mm
)
2
(
A
)
Power cable length
(
m
)
indoor-outdoor
wire size x number
(
mm
)
2
Earth wire size
(
mm
)
2
280
24
27
5.5
29
26
Ø1.6mm x 3
Ø1.6mm
The specifications shown in the above table are for units without heaters. For units with heaters, refer
to the installation instructions or the construction instructions of the indoor unit.
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen
along the regulations in each country.
The cable specifications are based on the assumption that a metal or plastic conduit is used with no
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation
in effect in each country.
52X6
Auxilliary relay
(
for 52X
)
t°
[ ]
+
+
OR
6
7
WH
5 4 1
BL
BR
RD
OR
6
7
WH
5 4 1
BL
BR
RD
L
I P M
U V W
N
P
U
V W
CT
CONTROL
Intelligent power module
IPM
CM
3
〜
MS
M
M
M
M
CNI1
CNI3
(
WH
)
(
WH
)
Содержание FDF100VNVD
Страница 81: ... 80 80 11 PAC T 160 ...
Страница 82: ... 81 81 11 PAC T 160 ...
Страница 83: ... 82 82 11 PAC T 160 ...