-
145
-
'11 • P
A
C-T
-160
Models FDC100,125,140VN
●
Outdoor unit check points
Check items with the *mark when the power is ON.
*
LED1
(Yellow)
LED2
(Red)
LED1
(Green)
Must be conductive.
When fuse is blown,
replace it or check wiring.
L1
TB
PWB3
DM
52X1
L1
C1
DIP-IPM
RAM
RAM
63H
CM
A/F MODULE
INVERTER PWB
NOISE FILTER
PWB1
PWB2
CONTROL PWB
L1i
Red
Red
White
White
F 250V 30A
F
250V 8A
L1o
TB8
CT1
TB1
TB2
TB10
TB21
~
~
-
+
-
N2
P
L2
TB5
TB6
TB7
U
V
W
CNE
CNI4
CNI2
CNACT1
TB8
TB9
L1
+
TB7
Ni
No
CN1
N
1
2
3
CNA2
CNPS
LPT
CNTH
CNIP
CNIP
CNW
CNW2
2
2
CNE
CNH
CNR
CNS
CNEEV1
CNEEV2
CNFAN1
CNA1
CNI3
CNI1
18V
15V
FMO1
SM2
SM1
20S
CH1
THo-R2
THo-IPM
THo-A
THo-S
THo-D
THo-R1
Power supply check:
Measure the power supply L1,N
(It is normal if it is AC220-240V)
Noise filter check:
There should be continuity.
There should be no shorts between phases.
DC Reactor continuity Check:
Max 25m
Ω
Capacitor check:
Check for anomaly in appearance
such as damage, swelling, etc.
Check the power transistor
module if there is short, open, or
breakdown on the elements
LED1 (Yellow) Check :
1 ~ 6 times flash
(
Refer to page 121
)
Red
White
Blue
When the outdoor
unit fan motor is
abnormal.
(Refer to page 186)
LED2(Red) check:
1~5 time flash
(Refer to page 121)
F1 (250V, 2A)
F2 (250V, 4A)
(b)
Micr
o
in
ver
ter
series
Содержание FDF100VNVD
Страница 81: ... 80 80 11 PAC T 160 ...
Страница 82: ... 81 81 11 PAC T 160 ...
Страница 83: ... 82 82 11 PAC T 160 ...