4.3.2 Alarm History
When an alarm occurs, the alarm information is recorded. When the NC power is ON, an alarm is automatically recorded
in alarm history. Alarm information is recorded from the latest alarm to 512.
Alarm information recorded in the history is NC message displayed on "NC message" screen and alarm messages dis-
played on "PLC message" screen.
The range etc. of record are shown as follows:
Record condition: When an alarm occurs (When two or more alarms occur at the same time, up to five alarms are recorded.)
With multi-part system, 1st part system is given priority and recorded. (Following 2nd part system, 3rd
part system...)
Number of history: 512 alarms (Whole)
Range of record: NC alarm (alarm, warning), PLC alarm message
(1) The following alarms are not recorded on the alarm/warning screen.
Operation alarm
- External interlock axis exists (M01 0004)
- Cutting override zero (M01 0102)
- External feed rate zero (M01 0103)
- Block start interlock (M01 0109)
- Cutting block start interlock (M01 0110)
- Interference check invalidated (M01 0200)
- Rapid override zero (M01 0125)
- Sp-Sp polygon (G51.2) cut interlock (M01 1033)
"U50 PLC stopped" before the HMI screen starts up
Note
Содержание E80 Series
Страница 1: ......
Страница 7: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 23: ......
Страница 25: ......
Страница 28: ...1 1 IB 1501273 F System Basic Configuration ...
Страница 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Страница 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Страница 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Страница 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Страница 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Страница 166: ...5 139 IB 1501273 F Troubleshooting ...
Страница 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Страница 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Страница 194: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 167 IB 1501273 F FCU8 DX651 Mounting screw size M5 ...
Страница 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Страница 212: ......