M800/M80/E80 Series Maintenance Manual
3 Maintenance of the Drive Unit
53
IB-1501273-F
3.2 Durable Parts
A guide to the part replacement cycle is shown below. Note that these will differ according to the working conditions or en-
vironmental conditions, so replace the parts if any abnormality is found. Contact Mitsubishi branch or your dealer for repairs
or part replacements.
[MDS-E/EH Series]
[MDS-EJ/EJH Series]
[MDS-EM/EMH Series]
(1) Power smoothing capacitor:
The characteristics of the power smoothing capacitor will deteriorate due to the effect of ripple currents, etc. The ca-
pacitor life is greatly affected by the ambient temperature and working conditions. However, when used continuously
in a normal air-conditioned environment, (ambient temperature is an average of 40°C or less) the service life will be ten
years.
(2) Relays:
Contact faults will occur due to contact wear caused by the switching current. The service life will be reached after
100,000 cumulative switches (switching life) although this will differ according to the power capacity.
(3) Servo motor bearings:
The motor bearings should be replaced after 20,000 to 30,000 hours of rated load operation at the rated speed. This
will be affected by the operation state, but the bearings must be replaced when any abnormal noise or vibration is found
in the inspections.
(4) Servo motor oil seal, V-ring:
These parts should be replaced after 5,000 hours of operation at the rated speed. This will be affected by the operation
state, but these parts must be replaced if oil leaks, etc., are found in the inspections.
Part name
Standard replacement time
Remarks
Servo drive unit Smoothing capacitor 10 years
The standard replacement time is
a reference. Even if the standard
replacement time is not reached,
the part must be replaced if any ab-
normality is found.
Cooling fan
10,000 to 30,000 hours (2 to 3 years)
Battery
10,000 hours (for MDS-BAT6V1SET,
MDSBTBOX-LR2060)
Servo motor
Bearings
20,000 to 30,000 hours
Encoder
20,000 to 30,000 hours
Oil seal, V-ring
5,000 hours
Part name
Standard replacement time
Remarks
Servo drive unit Smoothing capacitor 10 years
The standard replacement time is
a reference. Even if the standard
replacement time is not reached,
the part must be replaced if any ab-
normality is found.
Cooling fan
10,000 to 30,000 hours (2 to 3 years)
Battery
10,000 hours (for MR-BAT6V1SET)
Servo motor
Bearings
20,000 to 30,000 hours
Encoder
20,000 to 30,000 hours
Oil seal, V-ring
5,000 hours
Part name
Standard replacement time
Remarks
Servo drive unit Smoothing capacitor 10 years
The standard replacement time is
a reference. Even if the standard
replacement time is not reached,
the part must be replaced if any ab-
normality is found.
Cooling fan
10,000 to 30,000 hours (2 to 3 years)
Battery
10,000 hours (for MR-BAT6V1SET,
MDSBTBOX-LR2060)
Servo motor
Bearings
20,000 to 30,000 hours
Encoder
20,000 to 30,000 hours
Oil seal, V-ring
5,000 hours
Содержание E80 Series
Страница 1: ......
Страница 7: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 23: ......
Страница 25: ......
Страница 28: ...1 1 IB 1501273 F System Basic Configuration ...
Страница 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Страница 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Страница 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Страница 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Страница 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Страница 166: ...5 139 IB 1501273 F Troubleshooting ...
Страница 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Страница 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Страница 194: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 167 IB 1501273 F FCU8 DX651 Mounting screw size M5 ...
Страница 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Страница 212: ......