M800/M80/E80 Series Maintenance Manual
4 Failure Diagnosis
102
IB-1501273-F
Control input 4H
This indicates the control signal input from NC to spindle. (bit8 to bitF)
BitC: M coil selection command
BitD: L coil selection command
BitE: Sub-motor selection command
Control input 5L
This indicates the control signal input from NC to spindle. (bit0 to bit7)
Control input 5H
This indicates the control signal input from NC to spindle. (bit8 to bitF)
BitB: Minimum excitation 2 changeover request
BitC: Speed gain set 2 changeover request
BitD: Zero point re-detection request
BitE: Increase holding power of spindle
Control input 6L
This indicates the control signal input from NC to spindle. (bit0 to bit7)
Bit0: OMR-FF control request
Control input 6H
This indicates the control signal input from NC to spindle. (bit8 to bitF)
Bit8: Drivers communication control request
Control output 1L
This indicates the control signal input from spindle to NC. (bit0 to bit7)
Bit0: In READY ON
Bit1: In Servo ON
Bit7: In alarm
Control output 1H
This indicates the control signal input from spindle to NC. (bit8 to bitF)
Bit8 to BitA: In torque limit selection
BitC: In-position
BitD: In torque limit
BitF: In warning
Control output 2L
This indicates the control signal input from spindle to NC. (bit0 to bit7)
Bit0: Z phase passed
Bit3: In zero speed
Bit7: In external emergency stop
Control output 2H
This indicates the control signal input from spindle to NC. (bit8 to bitF)
Bit9: In speed monitor
BitA: In door closed (controller)
BitB: In door closed (self drive unit)
Control output 3L
This indicates the control signal input from spindle to NC. (bit0 to bit7)
Control output 3H
This indicates the control signal input from spindle to NC. (bit8 to bitF)
Control output 4L
This indicates the control signal input from spindle to NC. (bit0 to bit7)
Bit0 to Bit2: In spindle control mode selection
Bit4: In gear changeover command
Bit5 to Bit6: In gear selection
Bit7: Magnetic pole position not set
Control output 4H
This indicates the control signal input from spindle to NC. (bit8 to bitF)
BitD: In L coil selection
Control output 5L
This indicates the control signal input from spindle to NC. (bit0 to bit7)
Bit0: Current detection
Bit1: Speed detection
Bit6: In coil changeover
Control output 5H
This indicates the control signal input from spindle to NC. (bit8 to bitF)
Bit9: 2nd speed detection
BitB: In minimum excitation rate 2 selection
BitC: In speed gain set 2 selection
BitD: Zero point re-detection complete
BitF: In 2nd in-position
Control output 6L
This indicates the control signal input from spindle to NC. (bit0 to bit7)
Bit0: In OMR-FF control
Control output 6H
This indicates the control signal input from spindle to NC. (bit8 to bitF)
Bit8: In drivers communication control
Unit type
This displays the spindle type.
Unit serial No.
This displays the spindle serial No.
Software version
This displays the software No. and version on the spindle side.
Display items
Details
Содержание E80 Series
Страница 1: ......
Страница 7: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 23: ......
Страница 25: ......
Страница 28: ...1 1 IB 1501273 F System Basic Configuration ...
Страница 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Страница 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Страница 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Страница 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Страница 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Страница 166: ...5 139 IB 1501273 F Troubleshooting ...
Страница 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Страница 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Страница 194: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 167 IB 1501273 F FCU8 DX651 Mounting screw size M5 ...
Страница 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Страница 212: ......