IB-1501273-F
6.1.1 All Backup
This section explains the procedures to back up NC data in a memory card in a batch.
(1) APLC data can be backed up only when the APLC release specification is valid.
Operation method
(1)
Press the menu [Backup].
The all backup screen is displayed.
<Note>
Press the
to cancel this process.
(2)
Press the [Y], [y] or [INPUT] key.
The backup starts.
"Executing" and "*" are displayed for the state of file un-
der processing.
<Note>
If any NC data file exists in the backup folder, the con-
firmation message "Overwrite this file? (Y/N)" ap-
pears. In this case, press the [Y], [y] or [INPUT] key
to start backup.
If the tool data is being sorted, the operation message
"File access error" is displayed and the backup can-
not be executed.
For the custom data, the backup cannot be canceled
during its execution.
Note
Содержание E80 Series
Страница 1: ......
Страница 7: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 23: ......
Страница 25: ......
Страница 28: ...1 1 IB 1501273 F System Basic Configuration ...
Страница 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Страница 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Страница 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Страница 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Страница 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Страница 166: ...5 139 IB 1501273 F Troubleshooting ...
Страница 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Страница 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Страница 194: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 167 IB 1501273 F FCU8 DX651 Mounting screw size M5 ...
Страница 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Страница 212: ......