M800/M80/E80 Series Maintenance Manual
4 Failure Diagnosis
128
IB-1501273-F
4.12 Application Error Detection
With the application error detection function, applications using the custom API library are automatically detected from all
applications that are operated in the display unit of M800 Series, and the presence and absence of responses are observed
at fixed intervals. Applications which give no response and remain unchanged for a period of time are detected as abnormal
and the log is saved.
(*) This function is valid on Windows-based display of M800W/M80W Series only.
The application error detection function does not particularly display the error message etc. when an error is detected, but
it saves information and data log to investigate the cause easily. On the input/output screen, saved log can be transferred
to SD card.
If the screen operation is disabled due to an error such as screen lock, turn the NC power OFF, then turn it ON again, and
output the log files to an SD card on the input/output screen.
List of the log to be saved
(*1) The timing to save the log.
No.
Information
Timing
for saving
(*1)
What you understand from
the information
Narrow the cause by combining
the information
NC side
PC side
Applica-
tion side
1 Application name in which the error
occurred.
Application name
Process ID
A
Application name in which the
error occurred.
○
○
○
2 The time the error detection function
started.
C
The elapsed time from when
the NC power is turned ON to
the error occurrence.
○
○
○
3 The time error occurred
The time error occurred
The time of error canceling
A
By comparing with the time of
various data, it can search the
information on when the error
occurred.
○
○
○
4 Connection state between PC and
NC
(Whether NC is working, and con-
firming the cable disconnection)
Result from confirming the con-
nection state to NC.
A
It can confirm the connection
state when the connection error
has occurred between PC and
NC.
○
○
-
5 History of key and touch screen.
The name of application which is
active.
Key code of the key which is held
down.
Coordinate which the touch screen
is touched.
B
It can confirm the operation
when the error has occurred.
-
-
○
A: When error is detected.
Observation application saves the log when the error has occurred.
B: Constant
It saves the given amount of log constantly.
It keeps saving logs even after the error detection, so presume the time when the error has occurred from the
time in the log.
C: When the error detection is started
Содержание E80 Series
Страница 1: ......
Страница 7: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 23: ......
Страница 25: ......
Страница 28: ...1 1 IB 1501273 F System Basic Configuration ...
Страница 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Страница 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Страница 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Страница 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Страница 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Страница 166: ...5 139 IB 1501273 F Troubleshooting ...
Страница 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Страница 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Страница 194: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 167 IB 1501273 F FCU8 DX651 Mounting screw size M5 ...
Страница 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Страница 212: ......