M800/M80/E80 Series Maintenance Manual
4 Failure Diagnosis
122
IB-1501273-F
Display items
Display items
Details
(1)
State
Display the history data and sampling data collection status.
History data
Display the history data collection status.
History collecting: History data collection is in progress.
History stop: History data collection is stopped.
Sampling data
Display the sampling data collection status.
Sampling: Sampling data collection is in progress.
Sampling stop: Sampling data collection is stopped.
Sampling invalid: Sampling data collection is disabled.
(2)
Sampling specifications Specify the part system, spindle, and servo axes where sampling data is to be collect-
ed.
System
Specify the part systems where sampling data is not to be collected.
Specify the part system in HEX.
When "0" is set, sampling is carried out for all part systems.
This setting is ignored if a non-existent part system is specified.
Spindle
Specify the spindle where sampling data is not to be collected.
Specify the part system in HEX.
When "0" is set, sampling is carried out for all spindles.
This setting is ignored if a non-existent spindle is specified.
Servo
Specify the servo axes where sampling data is not to be collected.
Specify the part system in HEX.
This setting is not system-specific.
When "0" is set, sampling is carried out for all axes.
This setting is ignored if a non-existent servo axis is specified.
(3)
Collecting data select
This selects the diagnosis data to be collected.
0: Collected.
1: Not collected.
Key history
This selects whether or not key history data is collected.
Alarm history
This selects whether or not alarm history data is collected.
PLC I/O history
This selects whether or not PLC input/output signal history data is collected.
AC alarm history
This selects whether or not AC power ON/OFF history data is collected.
Touch history
This selects whether or not touchscreen history data is collected.
Tool ofs change
This selects whether or not tool offset change history data is collected.
Workpiece ofs change This selects whether or not workpiece offset change history data is collected.
(1)
(2)
(3)
Содержание E80 Series
Страница 1: ......
Страница 7: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 23: ......
Страница 25: ......
Страница 28: ...1 1 IB 1501273 F System Basic Configuration ...
Страница 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Страница 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Страница 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Страница 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Страница 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Страница 166: ...5 139 IB 1501273 F Troubleshooting ...
Страница 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Страница 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Страница 194: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 167 IB 1501273 F FCU8 DX651 Mounting screw size M5 ...
Страница 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Страница 212: ......