4.4.1.3 Carrying Out One-shot Output
The one-shot type PLC interface signal forced output is forcibly output only once during the screen operations. Thus, it may
not be possible to confirm the PLC interface signals updated with the PLC on the screen.
(1) Because the input signal (X, etc.) to the PLC is updated at the head of each PLC cycle, the machine immediately returns
to the normal state, even if one-shot type forced output is carried out.
(2) When no data is set (Example: "X0048/","X0048"), the operation message "Setting Data not found" is displayed.
(3) The X, Y, R, and ZR devices are one-shot output for all projects.
(4) The devices other than X, Y, R, and ZR are one-shot output for the currently displayed project.
One-shot outputting data "1" to device "X0042"
(1)
Press the menu [Next Project].
The display is switched to the I/O signal of the next proj-
ect.
(Press the menu key to switch the project in order.)
(2)
Press the menu [1-shot output].
(3)
Set the device and data, and press the [INPUT] key.
The input data is overwritten in the one-shot output area,
and is one-shot output.
The cursor in the one-shot output area disappears.
The data of the one-shot output device is displayed in or-
der in the selected area.
X0042/1 [INPUT]
The one-shot output mode is canceled by pressing
the
key or the
key.
CAUTION
Pay close attention to the sequence operation when carrying out forced data setting (forced output) in the I/F diag-
nosis screen during machine operation.
Note
Содержание E80 Series
Страница 1: ......
Страница 7: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 23: ......
Страница 25: ......
Страница 28: ...1 1 IB 1501273 F System Basic Configuration ...
Страница 68: ...2 41 IB 1501273 F Daily Maintenance and Periodic Maintenance ...
Страница 78: ...3 51 IB 1501273 F Maintenance of the Drive Unit ...
Страница 101: ...M800 M80 E80 Series Maintenance Manual 3 Maintenance of the Drive Unit 74 IB 1501273 F ...
Страница 102: ...4 75 IB 1501273 F Failure Diagnosis ...
Страница 165: ...M800 M80 E80 Series Maintenance Manual 4 Failure Diagnosis 138 IB 1501273 F ...
Страница 166: ...5 139 IB 1501273 F Troubleshooting ...
Страница 169: ...M800 M80 E80 Series Maintenance Manual 5 Troubleshooting 142 IB 1501273 F ...
Страница 170: ...6 143 IB 1501273 F Replacing Each Unit ...
Страница 194: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 167 IB 1501273 F FCU8 DX651 Mounting screw size M5 ...
Страница 205: ...M800 M80 E80 Series Maintenance Manual 6 Replacing Each Unit 178 IB 1501273 F ...
Страница 212: ......