74
SX-200 ICP CX/CXi Technician’s Handbook
Enabling MOSS Options
MOSS options provide additional functionality or capacity to the system. If
this is a new system and you have purchased options, such as additional
voice mailboxes or additional IP set licenses, you must enable them.
To enable MOSS options:
1.
Select Form 04.
2.
Press ENTER MOC and enter the Mitel Options Code printed on the
MOSS Sheet that is included with the system software package.
3.
Enter the Mitel Options password to activate the purchased options. The
password must be the password that is printed on the MOSS sheet.
4.
Program any other required options.
5.
Select Confirm if prompted to reset the controller.
6.
After the system resets, go into Maintenance and revise Alarm
Thresholds to prevent unnecessary alarms.
.
Notes:
1.
Attempts to enable unpurchased options causes the system to
respond with PASSWORD/OPTIONS CONFLICT -- "QUIT" TO
EXIT -- "ENTER" TO RE-EDIT. Conflicts are resolved by
entering the correct password; a system reset is not required.
2.
The system warns if changing an option requires a reset. The
reset is automatic and occurs when the change is confirmed.
3.
A MOSS alarm message in the CDE forms header indicates that
the System ID and Password do not match the database (occurs
when a database from another system is installed in the
controller). Enabling the options using the above procedure
clears the alarm.
Содержание SX-200 ICP - 1.0 5020
Страница 1: ...Release 4 0 CX CXi Controller TECHNICIAN S HANDBOOK ...
Страница 9: ...Chapter 1 Introduction ...
Страница 10: ...2 SX 200 ICP CX CXi Technician s Handbook ...
Страница 18: ...10 SX 200 ICP CX CXi Technician s Handbook Figure 1 Basic SX 200 ICP System CXi controller shown ...
Страница 24: ...16 SX 200 ICP CX CXi Technician s Handbook ...
Страница 25: ...Chapter 2 Basic Installation ...
Страница 26: ...18 SX 200 ICP CX CXi Technician s Handbook ...
Страница 75: ...Chapter 3 Basic Programming ...
Страница 76: ...68 SX 200 ICP CX CXi Technician s Handbook ...
Страница 87: ...79 Basic Programming The programmable keys on 5212 and 5330 not shown IP Phones are numbered as follows ...
Страница 89: ...81 Basic Programming The keys on the 5412 PKM are numbered as follows ...
Страница 98: ...90 SX 200 ICP CX CXi Technician s Handbook Figure 10 Administrator Mailbox Menu ...
Страница 142: ...134 SX 200 ICP CX CXi Technician s Handbook ...
Страница 143: ...Chapter 4 Advanced Installation and Programming ...
Страница 144: ...136 SX 200 ICP CX CXi Technician s Handbook ...
Страница 183: ...Chapter 5 Routine Maintenance ...
Страница 184: ...176 SX 200 ICP CX CXi Technician s Handbook ...
Страница 219: ...Chapter 6 Basic Troubleshooting and Repair ...
Страница 220: ...212 SX 200 ICP CX CXi Technician s Handbook ...
Страница 245: ...Chapter 7 Advanced Troubleshooting and Repair ...
Страница 246: ...238 SX 200 ICP CX CXi Technician s Handbook ...
Страница 269: ...Appendix A Default Database Values ...
Страница 270: ...262 SX 200 ICP CX CXi Technician s Handbook ...
Страница 325: ...317 Default Database Values Form 55 Incoming Digits INCOMING DIGITS DID PREFIX DAY N1 N2 TENANT ...
Страница 326: ...318 SX 200 ICP CX CXi Technician s Handbook ...
Страница 327: ...Appendix B Part Numbers ...
Страница 328: ...320 SX 200 ICP CX CXi Technician s Handbook ...
Страница 336: ...328 SX 200 ICP CX CXi Technician s Handbook ...
Страница 337: ...Appendix C System Cabling ...
Страница 338: ...330 SX 200 ICP CX CXi Technician s Handbook ...
Страница 343: ...Appendix D Folio Views E Docs Tips ...
Страница 344: ...336 SX 200 ICP CX Technician s Handbook ...
Страница 348: ...340 SX 200 ICP CX Technician s Handbook ...
Страница 360: ... Trademark of Mitel Networks Corporation Copyright 2006 Corporation All rights reserved Mitel Networks ...