114
SX-200 ICP CX/CXi Technician’s Handbook
Running the Line Quality Test for LS Trunks
Run the Line Quality test to measure and program optimum audio
configuration settings (line length and impedance) for AMB CLASS
circuits.
1.
Form 13 (Audio Configuration subform)
-
Program the trunks so that one trunk provides milliwatt tone for all
other trunks in a loopback setup when the test is performed.
Sample setup (trunk 6 provides milliwatt tone):
Trunk #
Tel #
Milliwatt
1
1111001
6
2
1111002
6
3
1111003
6
4
1111004
6
5
1111005
6
6
1111006
1
2.
Switch to MTCE.
3.
Press
DIAGNOSTICS
LS_MEASURE
select LINE_QUALITY (for one trunk) or BATCH_QUAL (for all trunks)
Respond to the prompts to run the test.
When the test is complete, LENGTH and IMPEDANCE are
programmed automatically in Form 13 (Audio Configuration subform).
Note:
If the local CO provides a milliwatt tone number, do not configure
the loopback setup described above. Instead, enter the milliwatt tone
number in Form 13 (Trunk Circuit Descriptors) and run the Line
Quality test.
Note:
LENGTH and IMPEDANCE must be set to AUTO in order to
be programmed automatically when the test is run. Refer to the logs
to determine the actual settings for AUTO. To view the logs, press
DIAGNOSTICS > LS_MEASURE > TEST_RESULTS > ENTER.
Содержание SX-200 ICP - 1.0 5020
Страница 1: ...Release 4 0 CX CXi Controller TECHNICIAN S HANDBOOK ...
Страница 9: ...Chapter 1 Introduction ...
Страница 10: ...2 SX 200 ICP CX CXi Technician s Handbook ...
Страница 18: ...10 SX 200 ICP CX CXi Technician s Handbook Figure 1 Basic SX 200 ICP System CXi controller shown ...
Страница 24: ...16 SX 200 ICP CX CXi Technician s Handbook ...
Страница 25: ...Chapter 2 Basic Installation ...
Страница 26: ...18 SX 200 ICP CX CXi Technician s Handbook ...
Страница 75: ...Chapter 3 Basic Programming ...
Страница 76: ...68 SX 200 ICP CX CXi Technician s Handbook ...
Страница 87: ...79 Basic Programming The programmable keys on 5212 and 5330 not shown IP Phones are numbered as follows ...
Страница 89: ...81 Basic Programming The keys on the 5412 PKM are numbered as follows ...
Страница 98: ...90 SX 200 ICP CX CXi Technician s Handbook Figure 10 Administrator Mailbox Menu ...
Страница 142: ...134 SX 200 ICP CX CXi Technician s Handbook ...
Страница 143: ...Chapter 4 Advanced Installation and Programming ...
Страница 144: ...136 SX 200 ICP CX CXi Technician s Handbook ...
Страница 183: ...Chapter 5 Routine Maintenance ...
Страница 184: ...176 SX 200 ICP CX CXi Technician s Handbook ...
Страница 219: ...Chapter 6 Basic Troubleshooting and Repair ...
Страница 220: ...212 SX 200 ICP CX CXi Technician s Handbook ...
Страница 245: ...Chapter 7 Advanced Troubleshooting and Repair ...
Страница 246: ...238 SX 200 ICP CX CXi Technician s Handbook ...
Страница 269: ...Appendix A Default Database Values ...
Страница 270: ...262 SX 200 ICP CX CXi Technician s Handbook ...
Страница 325: ...317 Default Database Values Form 55 Incoming Digits INCOMING DIGITS DID PREFIX DAY N1 N2 TENANT ...
Страница 326: ...318 SX 200 ICP CX CXi Technician s Handbook ...
Страница 327: ...Appendix B Part Numbers ...
Страница 328: ...320 SX 200 ICP CX CXi Technician s Handbook ...
Страница 336: ...328 SX 200 ICP CX CXi Technician s Handbook ...
Страница 337: ...Appendix C System Cabling ...
Страница 338: ...330 SX 200 ICP CX CXi Technician s Handbook ...
Страница 343: ...Appendix D Folio Views E Docs Tips ...
Страница 344: ...336 SX 200 ICP CX Technician s Handbook ...
Страница 348: ...340 SX 200 ICP CX Technician s Handbook ...
Страница 360: ... Trademark of Mitel Networks Corporation Copyright 2006 Corporation All rights reserved Mitel Networks ...