Page 29
The narrow, horizontal bar below the diagram supports operator to
exactly determine the center of the reflector. The search bar
(illustrated in the adjacent graphic) clearly shows in which direction,
based on the center of the display, the probe needs to be moved to
locate the reflector center.
on following page shows a graphic of the display with search
bar and position of the probe for reflector type AL RO 12.
Subsequently start the measurement:
With search button pressed down, run measuring device back
30 cm; the measurement will start automatically, or
Release search button
Place the probe at the starting point of the measurement path
which is about 30 cm in front of the located reflector.
The option “
Measure” is displayed. Press the
key to start
measuring.
Please note:
Measurement starts
automatically
Put down the probe above
center of reflector
With search button
pressed down, run probe
back about 30 cm
Fig. 25 Reflector search