Troubleshooting
Problem
Possible
Cause
Suggested
Solution
Motor pulsates or
surges under load
(cont.)
Motor does not
reverse
Motor creeps when
INH and COM
terminals are shorted
or RB and COM
terminals are shorted.
2. Motor “bouncing”
in and out of torque
limit.
1. Bad switch
connection to DIR
and COM.
2. Reversing circuit
not working properly.
BAL trimpot not set
for zero speed.
2. Make sure motor
is not undersized for
load.
1. Check switch
connection to DIR
and COM.
2. Check reversing
circuit by shorting
DIR to COM with
jumper wire.
Calibrate BAL
trimpot (see page
37).
250-0281.qxd 4/4/01 11:16 AM Page 59